語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
The development of high speed separation systems for the miniaturization of liquid chromatography
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
The development of high speed separation systems for the miniaturization of liquid chromatography
作者:
Hersel, Arthur Allen.
面頁冊數:
137 p.
附註:
Director: Csaba Horvath.
附註:
Source: Dissertation Abstracts International, Volume: 65-03, Section: B, page: 1433.
Contained By:
Dissertation Abstracts International65-03B.
標題:
Engineering, Chemical.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3125211
ISBN:
0496725017
The development of high speed separation systems for the miniaturization of liquid chromatography
Hersel, Arthur Allen.
The development of high speed separation systems for the miniaturization of liquid chromatography
[electronic resource] - 137 p.
Director: Csaba Horvath.
Thesis (Ph.D.)--Yale University, 2004.
In addition to the design of new instruments novel monolithic column designs were developed to eliminate unwanted electrostatic interactions and/or maintain high electroosmotic flow (EOF). To maintain high EOF a monolithic column was constructed that incorporated a charged monomer into the polymer backbone. This produced a column that maintained a high EOF at a broad pH range. The second type of column discussed was a duplex column that eliminated unwanted electrostatic interactions by separation of the charged EOF generating section of the column from the neutral separation section.
ISBN: 0496725017Subjects--Topical Terms:
226989
Engineering, Chemical.
The development of high speed separation systems for the miniaturization of liquid chromatography
LDR
:03438nmm _2200301 _450
001
162513
005
20051017073454.5
008
230606s2004 eng d
020
$a
0496725017
035
$a
00149014
035
$a
162513
040
$a
UnM
$c
UnM
100
0
$a
Hersel, Arthur Allen.
$3
227655
245
1 4
$a
The development of high speed separation systems for the miniaturization of liquid chromatography
$h
[electronic resource]
300
$a
137 p.
500
$a
Director: Csaba Horvath.
500
$a
Source: Dissertation Abstracts International, Volume: 65-03, Section: B, page: 1433.
502
$a
Thesis (Ph.D.)--Yale University, 2004.
520
#
$a
In addition to the design of new instruments novel monolithic column designs were developed to eliminate unwanted electrostatic interactions and/or maintain high electroosmotic flow (EOF). To maintain high EOF a monolithic column was constructed that incorporated a charged monomer into the polymer backbone. This produced a column that maintained a high EOF at a broad pH range. The second type of column discussed was a duplex column that eliminated unwanted electrostatic interactions by separation of the charged EOF generating section of the column from the neutral separation section.
520
#
$a
Miniaturization of chromatographic columns offers several advantages over large bore conventional analytical (2.1--4.6 mm ID) columns, typically used today. One such advantage is the increase in mass sensitivity attributed to the reduced column I.D., providing reduced dilution of the chromatographic band. In our lab we have constructed a triskelion instrument that can act as an HPLC, CEC or e-HPLC. The advantage of this configuration is that depending on the column architecture and sample complexity "tailor-made" separation schemes can be designed taking advantage of the either high temperature and/or the applied voltage. Mathematical models have been introduced to describe the effect of temperature on viscosity and analyte retention. In addition, models have been developed describing the quantitative relationships between the e-HPLC retention factor (k″) of charged analytes and the applied pressure and voltage. In the presences of an applied voltage intraparticle flow can become significant and reductions in the C-term of the Knox equations was accounted both experimentally and theoretically. Finally, the instrument was combined to a MALDI mass spectrometer by fraction collection, which allowed a protein digest to be separated and identified in approximately one minute.
520
#
$a
To characterize these newly developed monolithic a device was constructed to measure streaming current/potential, which enables measurement of column characteristics such as zeta potential, permeability, porosity, relative-hydrophobicity, and column efficiency. The above characteristics can be assessed using columns as short as 3cm allowing investigation of axial homogeneity. Surface conduction and the electroviscous effect were examined and corrections were made to assure the accuracy of the results.
590
$a
School code: 0265.
650
# 0
$a
Engineering, Chemical.
$3
226989
650
# 0
$a
Chemistry, Analytical.
$3
224793
690
$a
0486
690
$a
0542
710
0 #
$a
Yale University.
$3
212430
773
0 #
$g
65-03B.
$t
Dissertation Abstracts International
790
$a
0265
790
1 0
$a
Horvath, Csaba,
$e
advisor
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://libsw.nuk.edu.tw/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3125211
$z
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3125211
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000001006
電子館藏
1圖書
學位論文
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://libsw.nuk.edu.tw/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3125211
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入