A novel device to measure long-term oxygen therapy use: Design and application for identifying adherence patterns.
Record Type:
Electronic resources : Monograph/item
Title/Author:
A novel device to measure long-term oxygen therapy use: Design and application for identifying adherence patterns.
Author:
Lin, Sun-Kai.
Description:
118 p.
Notes:
Source: Dissertation Abstracts International, Volume: 66-06, Section: B, page: 3260.
Notes:
Supervisor: Daniel K. Bogen.
Contained By:
Dissertation Abstracts International66-06B.
Subject:
Engineering, Biomedical.
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3179768
ISBN:
9780542199110
A novel device to measure long-term oxygen therapy use: Design and application for identifying adherence patterns.
Lin, Sun-Kai.
A novel device to measure long-term oxygen therapy use: Design and application for identifying adherence patterns.
- 118 p.
Source: Dissertation Abstracts International, Volume: 66-06, Section: B, page: 3260.
Thesis (Ph.D.)--University of Pennsylvania, 2005.
Failure of patients to adhere to the medical treatment of chronic obstructive pulmonary disease (COPD) compromises patient health and increases health care costs. Current methods for measuring patient adherence to long-term oxygen therapy (LTOT) fail to measure the actual amount of time the patient is inhaling oxygen and the pattern of oxygen use within the day. A novel oxygen adherence monitor was developed to address these limitations. The monitor detects whether the oxygen source is turned on and whether the patient is inhaling oxygen through the nasal cannula. The monitor is based on sensing respiratory-related pressure fluctuations in the main oxygen delivery tube and is covertly placed in-line between the oxygen source and the patient. The accuracy of the monitor, as compared to direct-observation, was tested during exercise, daytime wakefulness, and sleep in patients with COPD on LTOT. Results showed that the monitor is capable of objectively measuring whether or not patients with COPD are receiving their treatment. Accuracy may be reduced in patients who are mouth breathers and/or who have frequent episodes of apnea/hypopnea. Beyond measuring the absolute level of adherence, objective monitoring also has the benefit of measuring patterns of therapy use. No systematic method exists for quantifying adherence patterns; thus, a new stochastic method to describe adherence patterns was introduced. The method treated adherence patterns as Markov chains, which allowed statistical comparisons between two patterns to determine if they were similar or not. Available data from asthma inhaler use and continuous positive airway pressure use were used for analysis since LTOT data was unavailable. Results indicated that the method could reliably distinguish between two different patterns. Clinical application of this novel technique may lead to new insights concerning predictors of adherence patterns and adherence promotion interventions for particular adherence patterns.
ISBN: 9780542199110Subjects--Topical Terms:
227004
Engineering, Biomedical.
A novel device to measure long-term oxygen therapy use: Design and application for identifying adherence patterns.
LDR
:03003nmm _2200265 _450
001
170710
005
20061228142225.5
008
090528s2005 eng d
020
$a
9780542199110
035
$a
00242740
040
$a
UnM
$c
UnM
100
0
$a
Lin, Sun-Kai.
$3
244738
245
1 2
$a
A novel device to measure long-term oxygen therapy use: Design and application for identifying adherence patterns.
300
$a
118 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-06, Section: B, page: 3260.
500
$a
Supervisor: Daniel K. Bogen.
502
$a
Thesis (Ph.D.)--University of Pennsylvania, 2005.
520
#
$a
Failure of patients to adhere to the medical treatment of chronic obstructive pulmonary disease (COPD) compromises patient health and increases health care costs. Current methods for measuring patient adherence to long-term oxygen therapy (LTOT) fail to measure the actual amount of time the patient is inhaling oxygen and the pattern of oxygen use within the day. A novel oxygen adherence monitor was developed to address these limitations. The monitor detects whether the oxygen source is turned on and whether the patient is inhaling oxygen through the nasal cannula. The monitor is based on sensing respiratory-related pressure fluctuations in the main oxygen delivery tube and is covertly placed in-line between the oxygen source and the patient. The accuracy of the monitor, as compared to direct-observation, was tested during exercise, daytime wakefulness, and sleep in patients with COPD on LTOT. Results showed that the monitor is capable of objectively measuring whether or not patients with COPD are receiving their treatment. Accuracy may be reduced in patients who are mouth breathers and/or who have frequent episodes of apnea/hypopnea. Beyond measuring the absolute level of adherence, objective monitoring also has the benefit of measuring patterns of therapy use. No systematic method exists for quantifying adherence patterns; thus, a new stochastic method to describe adherence patterns was introduced. The method treated adherence patterns as Markov chains, which allowed statistical comparisons between two patterns to determine if they were similar or not. Available data from asthma inhaler use and continuous positive airway pressure use were used for analysis since LTOT data was unavailable. Results indicated that the method could reliably distinguish between two different patterns. Clinical application of this novel technique may lead to new insights concerning predictors of adherence patterns and adherence promotion interventions for particular adherence patterns.
590
$a
School code: 0175.
650
# 0
$a
Engineering, Biomedical.
$3
227004
650
# 0
$a
Health Sciences, Rehabilitation and Therapy.
$3
212859
690
$a
0382
690
$a
0541
710
0 #
$a
University of Pennsylvania.
$3
212781
773
0 #
$g
66-06B.
$t
Dissertation Abstracts International
790
$a
0175
790
1 0
$a
Bogen, Daniel K.,
$e
advisor
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3179768
$z
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3179768
based on 0 review(s)
ALL
電子館藏
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
000000002508
電子館藏
1圖書
學位論文
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Multimedia file
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3179768
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login