語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
An inverse-geometry volumetric CT sy...
~
Schmidt, Taly Gilat.
An inverse-geometry volumetric CT system.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
An inverse-geometry volumetric CT system.
作者:
Schmidt, Taly Gilat.
面頁冊數:
94 p.
附註:
Adviser: Norbert J. Pelc.
附註:
Source: Dissertation Abstracts International, Volume: 66-08, Section: B, page: 4410.
Contained By:
Dissertation Abstracts International66-08B.
標題:
Engineering, Electronics and Electrical.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3186394
ISBN:
9780542286872
An inverse-geometry volumetric CT system.
Schmidt, Taly Gilat.
An inverse-geometry volumetric CT system.
- 94 p.
Adviser: Norbert J. Pelc.
Thesis (Ph.D.)--Stanford University, 2005.
Despite numerous advances in computed tomography (CT) imaging, a truly volumetric scanner, that is a system which acquires a complete dataset of a thick volume in one fast circular scan, has yet to be realized. While CT systems capable of acquiring multiple slices per gantry rotation are available, these cone-beam systems do not sufficiently sample the volume in one circular scan. The volume thickness covered in a single rotation by current multi-slice scanners is relatively small and the resulting cone-beam artifacts are negligible. As the acquired volume thickness, and therefore the cone-angle, increases, so do the artifacts. Exact reconstruction is possible for certain helical cone-beam geometries, but multiple rotations and table motion are required.
ISBN: 9780542286872Subjects--Topical Terms:
226981
Engineering, Electronics and Electrical.
An inverse-geometry volumetric CT system.
LDR
:03438nmm _2200313 _450
001
170782
005
20061228142244.5
008
090528s2005 eng d
020
$a
9780542286872
035
$a
00242812
040
$a
UnM
$c
UnM
100
0
$a
Schmidt, Taly Gilat.
$3
244812
245
1 3
$a
An inverse-geometry volumetric CT system.
300
$a
94 p.
500
$a
Adviser: Norbert J. Pelc.
500
$a
Source: Dissertation Abstracts International, Volume: 66-08, Section: B, page: 4410.
502
$a
Thesis (Ph.D.)--Stanford University, 2005.
520
#
$a
Despite numerous advances in computed tomography (CT) imaging, a truly volumetric scanner, that is a system which acquires a complete dataset of a thick volume in one fast circular scan, has yet to be realized. While CT systems capable of acquiring multiple slices per gantry rotation are available, these cone-beam systems do not sufficiently sample the volume in one circular scan. The volume thickness covered in a single rotation by current multi-slice scanners is relatively small and the resulting cone-beam artifacts are negligible. As the acquired volume thickness, and therefore the cone-angle, increases, so do the artifacts. Exact reconstruction is possible for certain helical cone-beam geometries, but multiple rotations and table motion are required.
520
#
$a
We began the IGCT investigation by examining several feasibility issues, for example the trade-off between scan time and sampling and the signal-to-noise ratio relative to a conventional system. A three-dimensional reconstruction algorithm was developed, and the artifact, resolution, and noise performance of the algorithm examined through computer simulations. A prototype table-top IGCT scanner was implemented based on a Scanning-Beam Digital X-ray system (NexRay, Inc., Los Gatos, CA) and several experiments performed to characterize the prototype system. Experimental results were compared to theoretical predictions and computer simulations. The results demonstrated that sufficient sampling of a 15-cm thick volume is possible in less than 0.5 seconds. The proposed algorithm can accurately reconstruct the volume without introducing significant artifacts, blurring, or noise. The results of the prototype system experiments demonstrate 0.25-mm isotropic resolution, acceptable noise performance, and improved image quality compared to conventional systems. Overall, the IGCT system shows promise for clinical scanning of a thick volume in one fast circular rotation with high resolution and no cone-beam effects.
520
#
$a
We present a new approach for volumetric CT imaging based on an inverse geometry which is capable of complete volumetric acquisition in one fast circular scan. The proposed inverse-geometry CT (IGCT) system utilizes a large-area scanned x-ray source and a narrower detector array. In the in-plane direction the sampling is fan-like, and because the source and detector have the same extent in the slice direction, sufficient volumetric sampling is achieved.
590
$a
School code: 0212.
650
# 0
$a
Engineering, Electronics and Electrical.
$3
226981
650
# 0
$a
Engineering, Biomedical.
$3
227004
650
# 0
$a
Health Sciences, Radiology.
$3
227298
650
# 0
$a
Biophysics, Medical.
$3
227040
690
$a
0541
690
$a
0544
690
$a
0574
690
$a
0760
710
0 #
$a
Stanford University.
$3
212607
773
0 #
$g
66-08B.
$t
Dissertation Abstracts International
790
$a
0212
790
1 0
$a
Pelc, Norbert J.,
$e
advisor
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3186394
$z
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3186394
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000002580
電子館藏
1圖書
學位論文
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3186394
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入