Integration of X-ray and MRI systems.
~
Stanford University.
Integration of X-ray and MRI systems.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Integration of X-ray and MRI systems.
作者:
Wen, Zhifei.
面頁冊數:
156 p.
附註:
Adviser: Norbert J. Pelc.
附註:
Source: Dissertation Abstracts International, Volume: 66-08, Section: B, page: 4268.
Contained By:
Dissertation Abstracts International66-08B.
標題:
Physics, General.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3186417
ISBN:
9780542287206
Integration of X-ray and MRI systems.
Wen, Zhifei.
Integration of X-ray and MRI systems.
- 156 p.
Adviser: Norbert J. Pelc.
Thesis (Ph.D.)--Stanford University, 2005.
X-ray fluoroscopic imaging provides two-dimensional (2D) projection images with high temporal and spatial resolutions, while magnetic resonance imaging (MRI) has the ability to image any plane in 3D space with excellent soft tissue contrast and powerful physiological information. Integration of these two complementary imaging modalities can greatly benefit numerous image-guided minimally invasive procedures. At Stanford, an x-ray/MR hybrid system has been developed by placing an x-ray tube and detector inside the magnet of an open-bore interventional MR scanner in a configuration without requiring patient movement. However, the proximity of the two systems can cause one to degrade the performance of the other. The influence on the x-ray system by the MR system mainly results from its magnetic field at the location of the x-ray tube. If the magnetic field is parallel to the axis of the tube, it can change the size and shape of the x-ray focal spot by affecting the trajectories of the primary electrons, and increase the tube output by confining the backscattered electrons. If the magnetic field is misaligned with the tube axis, the electron beam can be deflected. These effects are studied analytically, numerically and experimentally. Experimental data agree well with theoretic analysis and computer simulations. Modifications to the x-ray tube are proposed to make it more robust for working in a misaligned magnetic field. The impact on the MR system from the x-ray system stems from the x-ray detector placed underneath the patient table near the MR imaging volume. Magnetic components inside the detector can be magnetized in the magnetic field and create an additional magnetic field that degrades the field homogeneity of the MR system. We use rare-earth permanent magnets located proximate to the detector to compensate for the unwanted field. The strengths and locations of the magnets are optimized with the measured detector field and the MR image quality is significantly improved after shim magnets are deployed. Our work effectively minimized interferences between the x-ray and MR systems. Clinical procedures performed with our system show great promise for enhanced diagnosis and improved guidance of therapy.
ISBN: 9780542287206Subjects--Topical Terms:
227017
Physics, General.
Integration of X-ray and MRI systems.
LDR
:03180nmm _2200277 _450
001
170790
005
20061228142246.5
008
090528s2005 eng d
020
$a
9780542287206
035
$a
00242820
040
$a
UnM
$c
UnM
100
0
$a
Wen, Zhifei.
$3
244821
245
1 0
$a
Integration of X-ray and MRI systems.
300
$a
156 p.
500
$a
Adviser: Norbert J. Pelc.
500
$a
Source: Dissertation Abstracts International, Volume: 66-08, Section: B, page: 4268.
502
$a
Thesis (Ph.D.)--Stanford University, 2005.
520
#
$a
X-ray fluoroscopic imaging provides two-dimensional (2D) projection images with high temporal and spatial resolutions, while magnetic resonance imaging (MRI) has the ability to image any plane in 3D space with excellent soft tissue contrast and powerful physiological information. Integration of these two complementary imaging modalities can greatly benefit numerous image-guided minimally invasive procedures. At Stanford, an x-ray/MR hybrid system has been developed by placing an x-ray tube and detector inside the magnet of an open-bore interventional MR scanner in a configuration without requiring patient movement. However, the proximity of the two systems can cause one to degrade the performance of the other. The influence on the x-ray system by the MR system mainly results from its magnetic field at the location of the x-ray tube. If the magnetic field is parallel to the axis of the tube, it can change the size and shape of the x-ray focal spot by affecting the trajectories of the primary electrons, and increase the tube output by confining the backscattered electrons. If the magnetic field is misaligned with the tube axis, the electron beam can be deflected. These effects are studied analytically, numerically and experimentally. Experimental data agree well with theoretic analysis and computer simulations. Modifications to the x-ray tube are proposed to make it more robust for working in a misaligned magnetic field. The impact on the MR system from the x-ray system stems from the x-ray detector placed underneath the patient table near the MR imaging volume. Magnetic components inside the detector can be magnetized in the magnetic field and create an additional magnetic field that degrades the field homogeneity of the MR system. We use rare-earth permanent magnets located proximate to the detector to compensate for the unwanted field. The strengths and locations of the magnets are optimized with the measured detector field and the MR image quality is significantly improved after shim magnets are deployed. Our work effectively minimized interferences between the x-ray and MR systems. Clinical procedures performed with our system show great promise for enhanced diagnosis and improved guidance of therapy.
590
$a
School code: 0212.
650
# 0
$a
Physics, General.
$3
227017
650
# 0
$a
Health Sciences, Radiology.
$3
227298
650
# 0
$a
Engineering, Biomedical.
$3
227004
690
$a
0541
690
$a
0574
690
$a
0605
710
0 #
$a
Stanford University.
$3
212607
773
0 #
$g
66-08B.
$t
Dissertation Abstracts International
790
$a
0212
790
1 0
$a
Pelc, Norbert J.,
$e
advisor
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3186417
$z
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3186417
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000002588
電子館藏
1圖書
學位論文
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3186417
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入