語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Stimulation and recording electrodes...
~
Kaim, Hans.
Stimulation and recording electrodes for neural prostheses
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Stimulation and recording electrodes for neural prosthesesby Naser Pour Aryan, Hans Kaim, Albrecht Rothermel.
作者:
Pour Aryan, Naser.
其他作者:
Kaim, Hans.
出版者:
Cham :Springer International Publishing :2015.
面頁冊數:
xii, 81 p. :ill. (some col.), digital ;24 cm.
Contained By:
Springer eBooks
標題:
Neuroprostheses.
電子資源:
http://dx.doi.org/10.1007/978-3-319-10052-4
ISBN:
9783319100524 (electronic bk.)
Stimulation and recording electrodes for neural prostheses
Pour Aryan, Naser.
Stimulation and recording electrodes for neural prostheses
[electronic resource] /by Naser Pour Aryan, Hans Kaim, Albrecht Rothermel. - Cham :Springer International Publishing :2015. - xii, 81 p. :ill. (some col.), digital ;24 cm. - SpringerBriefs in electrical and computer engineering,782191-8112 ;. - SpringerBriefs in electrical and computer engineering ;74..
Stimulation and recording electrodes: General concepts -- Irreversible and reversible redox reactions: Water window -- Charge balance and safe operation conditions -- Primary current distribution and electrode geometry -- Experiments hardware and methods -- Electrode materials: State-of-the-art and experiments -- The effect of the counter electrode on stimulation electrode lifetime -- Electrode modeling for titanium nitride, iridium and iridium oxide microelectrodes -- Summary.
This book provides readers with basic principles of the electrochemistry of the electrodes used in modern, implantable neural prostheses. The authors discuss the boundaries and conditions in which the electrodes continue to function properly for long time spans, which are required when designing neural stimulator devices for long-term in vivo applications. Two kinds of electrode materials, titanium nitride and iridium are discussed extensively, both qualitatively and quantitatively. The influence of the counter electrode on the safety margins and electrode lifetime in a two electrode system is explained. Electrode modeling is handled in a final chapter.
ISBN: 9783319100524 (electronic bk.)
Standard No.: 10.1007/978-3-319-10052-4doiSubjects--Topical Terms:
710770
Neuroprostheses.
LC Class. No.: R856
Dewey Class. No.: 610.28
Stimulation and recording electrodes for neural prostheses
LDR
:02192nmm a2200325 a 4500
001
459791
003
DE-He213
005
20150603091143.0
006
m d
007
cr nn 008maaau
008
151110s2015 gw s 0 eng d
020
$a
9783319100524 (electronic bk.)
020
$a
9783319100517 (paper)
024
7
$a
10.1007/978-3-319-10052-4
$2
doi
035
$a
978-3-319-10052-4
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
R856
072
7
$a
TJFC
$2
bicssc
072
7
$a
TEC008010
$2
bisacsh
082
0 4
$a
610.28
$2
23
090
$a
R856
$b
.P877 2015
100
1
$a
Pour Aryan, Naser.
$3
710522
245
1 0
$a
Stimulation and recording electrodes for neural prostheses
$h
[electronic resource] /
$c
by Naser Pour Aryan, Hans Kaim, Albrecht Rothermel.
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2015.
300
$a
xii, 81 p. :
$b
ill. (some col.), digital ;
$c
24 cm.
490
1
$a
SpringerBriefs in electrical and computer engineering,
$x
2191-8112 ;
$v
78
505
0
$a
Stimulation and recording electrodes: General concepts -- Irreversible and reversible redox reactions: Water window -- Charge balance and safe operation conditions -- Primary current distribution and electrode geometry -- Experiments hardware and methods -- Electrode materials: State-of-the-art and experiments -- The effect of the counter electrode on stimulation electrode lifetime -- Electrode modeling for titanium nitride, iridium and iridium oxide microelectrodes -- Summary.
520
$a
This book provides readers with basic principles of the electrochemistry of the electrodes used in modern, implantable neural prostheses. The authors discuss the boundaries and conditions in which the electrodes continue to function properly for long time spans, which are required when designing neural stimulator devices for long-term in vivo applications. Two kinds of electrode materials, titanium nitride and iridium are discussed extensively, both qualitatively and quantitatively. The influence of the counter electrode on the safety margins and electrode lifetime in a two electrode system is explained. Electrode modeling is handled in a final chapter.
650
0
$a
Neuroprostheses.
$3
710770
650
0
$a
Microelectrodes.
$3
240233
650
1 4
$a
Engineering.
$3
210888
650
2 4
$a
Circuits and Systems.
$3
274416
650
2 4
$a
Biomedical Engineering.
$3
190464
700
1
$a
Kaim, Hans.
$3
710768
700
1
$a
Rothermel, Albrecht.
$3
710769
710
2
$a
SpringerLink (Online service)
$3
273601
773
0
$t
Springer eBooks
830
0
$a
SpringerBriefs in electrical and computer engineering ;
$v
74.
$3
678490
856
4 0
$u
http://dx.doi.org/10.1007/978-3-319-10052-4
950
$a
Engineering (Springer-11647)
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000109298
電子館藏
1圖書
電子書
EB R856 P877 2015
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://dx.doi.org/10.1007/978-3-319-10052-4
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入