語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Advanced connection systems for arch...
~
Khoraskani, Roham Afghani.
Advanced connection systems for architectural glazing
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Advanced connection systems for architectural glazingby Roham Afghani Khoraskani.
作者:
Khoraskani, Roham Afghani.
出版者:
Cham :Springer International Publishing :2015.
面頁冊數:
viii, 125 p. :ill., digital ;24 cm.
Contained By:
Springer eBooks
標題:
Glass construction.
電子資源:
http://dx.doi.org/10.1007/978-3-319-12997-6
ISBN:
9783319129976 (electronic bk.)
Advanced connection systems for architectural glazing
Khoraskani, Roham Afghani.
Advanced connection systems for architectural glazing
[electronic resource] /by Roham Afghani Khoraskani. - Cham :Springer International Publishing :2015. - viii, 125 p. :ill., digital ;24 cm. - SpringerBriefs in applied sciences and technology,2191-530X. - SpringerBriefs in applied sciences and technology..
From the Contents: Building envelope and mechanical compatibility with building structure -- Glass curtain wall systems and seismic behavior -- Advanced connection devices for building envelope systems -- Rotational friction connection devices: a novel approach towards friction connection devices for glazed envelope systems.
This book presents the findings of a detailed study to explore the behavior of architectural glazing systems during and after an earthquake and to develop design proposals that will mitigate or even eliminate the damage inflicted on these systems. The seismic behavior of common types of architectural glazing systems are investigated and causes of damage to each system, identified. Furthermore, depending on the geometrical and structural characteristics, the ultimate horizontal load capacity of glass curtain wall systems is defined based on the stability of the glass components. Detailed attention is devoted to the incorporation of advanced connection devices between the structure of the building and the building envelope system in order to minimize the damage to glazed components. An innovative new connection device is introduced that results in a delicate and functional system easily incorporated into different architectural glazing systems, including those demanding maximum transparency.
ISBN: 9783319129976 (electronic bk.)
Standard No.: 10.1007/978-3-319-12997-6doiSubjects--Topical Terms:
214441
Glass construction.
LC Class. No.: NA4140
Dewey Class. No.: 693.96
Advanced connection systems for architectural glazing
LDR
:02362nmm a2200337 a 4500
001
462645
003
DE-He213
005
20151026160241.0
006
m d
007
cr nn 008maaau
008
151119s2015 gw s 0 eng d
020
$a
9783319129976 (electronic bk.)
020
$a
9783319129969 (paper)
024
7
$a
10.1007/978-3-319-12997-6
$2
doi
035
$a
978-3-319-12997-6
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
NA4140
072
7
$a
TNK
$2
bicssc
072
7
$a
TNKH
$2
bicssc
072
7
$a
TEC005050
$2
bisacsh
082
0 4
$a
693.96
$2
23
090
$a
NA4140
$b
.K45 2015
100
1
$a
Khoraskani, Roham Afghani.
$3
715727
245
1 0
$a
Advanced connection systems for architectural glazing
$h
[electronic resource] /
$c
by Roham Afghani Khoraskani.
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2015.
300
$a
viii, 125 p. :
$b
ill., digital ;
$c
24 cm.
490
1
$a
SpringerBriefs in applied sciences and technology,
$x
2191-530X
505
0
$a
From the Contents: Building envelope and mechanical compatibility with building structure -- Glass curtain wall systems and seismic behavior -- Advanced connection devices for building envelope systems -- Rotational friction connection devices: a novel approach towards friction connection devices for glazed envelope systems.
520
$a
This book presents the findings of a detailed study to explore the behavior of architectural glazing systems during and after an earthquake and to develop design proposals that will mitigate or even eliminate the damage inflicted on these systems. The seismic behavior of common types of architectural glazing systems are investigated and causes of damage to each system, identified. Furthermore, depending on the geometrical and structural characteristics, the ultimate horizontal load capacity of glass curtain wall systems is defined based on the stability of the glass components. Detailed attention is devoted to the incorporation of advanced connection devices between the structure of the building and the building envelope system in order to minimize the damage to glazed components. An innovative new connection device is introduced that results in a delicate and functional system easily incorporated into different architectural glazing systems, including those demanding maximum transparency.
650
0
$a
Glass construction.
$3
214441
650
0
$a
Facades.
$3
257311
650
0
$a
Joints (Engineering)
$3
210854
650
1 4
$a
Engineering.
$3
210888
650
2 4
$a
Building Construction.
$3
511625
650
2 4
$a
Vibration, Dynamical Systems, Control.
$3
274667
650
2 4
$a
Ceramics, Glass, Composites, Natural Methods.
$3
274184
710
2
$a
SpringerLink (Online service)
$3
273601
773
0
$t
Springer eBooks
830
0
$a
SpringerBriefs in applied sciences and technology.
$3
557662
856
4 0
$u
http://dx.doi.org/10.1007/978-3-319-12997-6
950
$a
Engineering (Springer-11647)
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000112348
電子館藏
1圖書
電子書
EB NA4140 K45 2015
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://dx.doi.org/10.1007/978-3-319-12997-6
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入