語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Best practices for commercial roof-m...
~
SpringerLink (Online service)
Best practices for commercial roof-mounted photovoltaic system installation
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Best practices for commercial roof-mounted photovoltaic system installationby Rosalie Wills ... [et al.].
其他作者:
Wills, Rosalie.
出版者:
New York, NY :Springer New York :2015.
面頁冊數:
xiv, 76 p. :ill., digital ;24 cm.
Contained By:
Springer eBooks
標題:
Building-integrated photovoltaic systemsSafety measures.
電子資源:
http://dx.doi.org/10.1007/978-1-4939-2883-5
ISBN:
9781493928835 (electronic bk.)
Best practices for commercial roof-mounted photovoltaic system installation
Best practices for commercial roof-mounted photovoltaic system installation
[electronic resource] /by Rosalie Wills ... [et al.]. - New York, NY :Springer New York :2015. - xiv, 76 p. :ill., digital ;24 cm. - SpringerBriefs in fire,2193-6595. - SpringerBriefs in fire..
Introduction -- Structural Loading -- Wind Loads -- Hail -- Snow -- Debris Accumulation -- Seismic -- Fire Hazards -- Electrical Hazards Associated with Fire Fighter Operations -- Weather-related Maintenance Considerations -- Compilation of Best Practices -- Hazard Gap Analysis.
This SpringerBrief presents information on a wide variety of hazards and the damage potential caused by installation of a photovoltaic (PV) system. The current installation practices for PV systems on roofs create electrical, fire, structural, and weather-related hazards that do not comply to current codes, standards and guidance documents. Potential dangers include structural loading, wind loads, hail, snow, debris accumulation, seismic hazards, firefighting hazards, and electrical hazards. Despite the increased popularity of PV systems after the environmental movement, research shows that the costs of installing PV systems outweigh the benefits. Hazards of PV systems on roofs have caused several incidents in the United States; the most notable in Bakersfield, California, and Mount Holly, North Carolina. Designed for fire engineers and professionals, Best Practices for Commercial Roof-Mounted Photovoltaic System Installation offers recommendations to set up PV systems safely and sustainably.
ISBN: 9781493928835 (electronic bk.)
Standard No.: 10.1007/978-1-4939-2883-5doiSubjects--Topical Terms:
724706
Building-integrated photovoltaic systems
--Safety measures.
LC Class. No.: TK1087
Dewey Class. No.: 621.31244
Best practices for commercial roof-mounted photovoltaic system installation
LDR
:02330nmm a2200337 a 4500
001
468926
003
DE-He213
005
20151224172411.0
006
m d
007
cr nn 008maaau
008
160118s2015 nyu s 0 eng d
020
$a
9781493928835 (electronic bk.)
020
$a
9781493928828 (paper)
024
7
$a
10.1007/978-1-4939-2883-5
$2
doi
035
$a
978-1-4939-2883-5
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
TK1087
072
7
$a
TNK
$2
bicssc
072
7
$a
TNKH
$2
bicssc
072
7
$a
TEC005050
$2
bisacsh
082
0 4
$a
621.31244
$2
23
090
$a
TK1087
$b
.B561 2015
245
0 0
$a
Best practices for commercial roof-mounted photovoltaic system installation
$h
[electronic resource] /
$c
by Rosalie Wills ... [et al.].
260
$a
New York, NY :
$b
Springer New York :
$b
Imprint: Springer,
$c
2015.
300
$a
xiv, 76 p. :
$b
ill., digital ;
$c
24 cm.
490
1
$a
SpringerBriefs in fire,
$x
2193-6595
505
0
$a
Introduction -- Structural Loading -- Wind Loads -- Hail -- Snow -- Debris Accumulation -- Seismic -- Fire Hazards -- Electrical Hazards Associated with Fire Fighter Operations -- Weather-related Maintenance Considerations -- Compilation of Best Practices -- Hazard Gap Analysis.
520
$a
This SpringerBrief presents information on a wide variety of hazards and the damage potential caused by installation of a photovoltaic (PV) system. The current installation practices for PV systems on roofs create electrical, fire, structural, and weather-related hazards that do not comply to current codes, standards and guidance documents. Potential dangers include structural loading, wind loads, hail, snow, debris accumulation, seismic hazards, firefighting hazards, and electrical hazards. Despite the increased popularity of PV systems after the environmental movement, research shows that the costs of installing PV systems outweigh the benefits. Hazards of PV systems on roofs have caused several incidents in the United States; the most notable in Bakersfield, California, and Mount Holly, North Carolina. Designed for fire engineers and professionals, Best Practices for Commercial Roof-Mounted Photovoltaic System Installation offers recommendations to set up PV systems safely and sustainably.
650
0
$a
Building-integrated photovoltaic systems
$x
Safety measures.
$3
724706
650
0
$a
Building-integrated photovoltaic systems
$x
Risk assessment.
$3
724707
650
0
$a
Fire prevention.
$3
226591
650
1 4
$a
Engineering.
$3
210888
650
2 4
$a
Building Construction.
$3
511625
650
2 4
$a
Structural Mechanics.
$3
274624
650
2 4
$a
Quality Control, Reliability, Safety and Risk.
$3
274011
700
1
$a
Wills, Rosalie.
$3
724705
710
2
$a
SpringerLink (Online service)
$3
273601
773
0
$t
Springer eBooks
830
0
$a
SpringerBriefs in fire.
$3
549758
856
4 0
$u
http://dx.doi.org/10.1007/978-1-4939-2883-5
950
$a
Computer Science (Springer-11645)
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000117356
電子館藏
1圖書
電子書
EB TK1087 B561 2015
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://dx.doi.org/10.1007/978-1-4939-2883-5
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入