語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Implicitly-coupled electromechanical...
~
Illinois Institute of Technology.
Implicitly-coupled electromechanical and electromagnetic transient analysis.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Implicitly-coupled electromechanical and electromagnetic transient analysis.
作者:
Zhang, Xu.
面頁冊數:
114 p.
附註:
Source: Dissertation Abstracts International, Volume: 76-12(E), Section: B.
附註:
Adviser: Alexander J. Flueck.
Contained By:
Dissertation Abstracts International76-12B(E).
標題:
Electrical engineering.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3664035
ISBN:
9781339100968
Implicitly-coupled electromechanical and electromagnetic transient analysis.
Zhang, Xu.
Implicitly-coupled electromechanical and electromagnetic transient analysis.
- 114 p.
Source: Dissertation Abstracts International, Volume: 76-12(E), Section: B.
Thesis (Ph.D.)--Illinois Institute of Technology, 2015.
The operation of an electrical power system involves continuous electromechanical and electromagnetic interaction of energy among the system components. Under normal operation, the system behavior could be represented by voltage and current phasors in the frequency domain. However, the system may not work on the fundamental frequency following some fast transients (loss of generator, switching event, system disturbance and etc.), at this time we need specific tools to investigate the dynamic scenario.
ISBN: 9781339100968Subjects--Topical Terms:
454503
Electrical engineering.
Implicitly-coupled electromechanical and electromagnetic transient analysis.
LDR
:03435nmm a2200313 4500
001
476046
005
20160418090145.5
008
160517s2015 ||||||||||||||||| ||eng d
020
$a
9781339100968
035
$a
(MiAaPQ)AAI3664035
035
$a
AAI3664035
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Zhang, Xu.
$3
683299
245
1 0
$a
Implicitly-coupled electromechanical and electromagnetic transient analysis.
300
$a
114 p.
500
$a
Source: Dissertation Abstracts International, Volume: 76-12(E), Section: B.
500
$a
Adviser: Alexander J. Flueck.
502
$a
Thesis (Ph.D.)--Illinois Institute of Technology, 2015.
520
$a
The operation of an electrical power system involves continuous electromechanical and electromagnetic interaction of energy among the system components. Under normal operation, the system behavior could be represented by voltage and current phasors in the frequency domain. However, the system may not work on the fundamental frequency following some fast transients (loss of generator, switching event, system disturbance and etc.), at this time we need specific tools to investigate the dynamic scenario.
520
$a
Transient stability (TS) simulator, also referred to as electromechanical transient simulator, running at time steps on the order of milliseconds and only capable of capturing the fundamental frequency transient, is used for the analysis of large-scale networks. On the other hand the electromagnetic transient (EMT) simulator running at time steps on the order of microseconds, with detailed equipment modeling is capable of analyzing transients over a wider frequency spectrum; however, it is computationally onerous, so it is typically restricted to the analysis of small networks.
520
$a
An electromechanical-electromagnetic transient simulator is the combination of a TS simulator and an EMT simulator, inheriting the merits of both programs The basic idea of an electromechanical-electromagnetic simulator is to decompose the power system into two broad categories: a large connected TS network (main network) and smaller EMT network (detailed subsystem). The main network is running on TS simulator while the detailed subsystem is running on the EMT simulator. The implicitly-coupled electromechanical and electromagnetic simulator has TS and EMT simulators coupled at the equation solution level, which could ensure the consistence of the solution between TS and EMT simulation.
520
$a
Instead of using fundamental frequency equivalent model of the main network in EMT simulation of implicitly-coupled electromechanical and electromagnetic simulator, a frequency dependent network equivalent (FDNE) model is utilized to preserve the non-fundamental frequency fast transient response of the main network.
520
$a
Along with the implementation of FDNE model, this research work also propose a new TS simulator that is capable of running three-phase transient stability simulation under fundamental and non-fundamental frequency simultaneously. Furthermore the performance of implicitly-coupled electromechanical-electromagnetic transient simulator could be improved with the implementation of this new TS simulator.
590
$a
School code: 0091.
650
4
$a
Electrical engineering.
$3
454503
690
$a
0544
710
2
$a
Illinois Institute of Technology.
$3
212580
773
0
$t
Dissertation Abstracts International
$g
76-12B(E).
790
$a
0091
791
$a
Ph.D.
792
$a
2015
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3664035
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000119396
電子館藏
1圖書
學位論文
TH 2015
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3664035
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入