Language:
English
繁體中文
Help
圖資館首頁
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Amperometric and impedance monitorin...
~
Punter-Villagrasa, Jaime.
Amperometric and impedance monitoring systems for biomedical applications
Record Type:
Electronic resources : Monograph/item
Title/Author:
Amperometric and impedance monitoring systems for biomedical applicationsby Jaime Punter-Villagrasa ... [et al.].
other author:
Punter-Villagrasa, Jaime.
Published:
Cham :Springer International Publishing :2017.
Description:
viii, 241 p. :ill., digital ;24 cm.
Contained By:
Springer eBooks
Subject:
Biomedical engineering.
Online resource:
http://dx.doi.org/10.1007/978-3-319-64801-9
ISBN:
9783319648019$q(electronic bk.)
Amperometric and impedance monitoring systems for biomedical applications
Amperometric and impedance monitoring systems for biomedical applications
[electronic resource] /by Jaime Punter-Villagrasa ... [et al.]. - Cham :Springer International Publishing :2017. - viii, 241 p. :ill., digital ;24 cm. - Bioanalysis, advanced materials, methods, and devices,v.42364-1118 ;. - Bioanalysis, advanced materials, methods, and devices ;1..
Acknowledgements -- Abstract -- Abbreviations -- Contents -- List Of Figures -- 1 Introduction -- 2 Electronics architectures Box -- 3 Design, Test and Validation of the proposed Architecture -- 4 Validation of the Pervasive Architecture with different applications -- 5 New Generation of POC Device: AN Hematrocrit (HCT) Detection Case -- 6 Conclusions -- Appendix A: Schematics, Design and Validation of Different Potentiostat Topologies -- Appendix B: Schematics, Design and Validation of an Electronic Device for EIS Applications -- Appendix C: Schematics, Design and Validation of the HCT POC Device.
The book presents the conception and realization of a pervasive electronic architecture for electrochemical applications, focusing on electronic instrumentation design and device development, particularly in electrochemical Point-of-Care and Lab-on-a-Chip devices, covering examples based on amperometric (DC) and impedance detection (AC) techniques. The presented electronics combine tailored front-end instrumentation and back-end data post-processing, enabling applications in different areas, and across a variety of techniques, analytes, transducers and environments. It addresses how the electronics are designed and implemented with special interest in the flow process: starting from electronic circuits and electrochemical biosensor design to a final validation and implementation for specific applications. Similarly, other important aspects are discussed throughout the book, such as electrochemical techniques, different analytes, targets, electronics reliability and robustness. The book also describes the use of the presented electronics in different electrochemical applications through some examples: instantaneous and non-destructive cellular monitoring and portable glucose monitoring device. Moreover, the book aims to introduce a comprehensive approach to electronic circuits, techniques and electrochemical sensors in POC devices to a general audience of students in biomedical and electronics engineering, scientists, and engineers.
ISBN: 9783319648019$q(electronic bk.)
Standard No.: 10.1007/978-3-319-64801-9doiSubjects--Topical Terms:
190330
Biomedical engineering.
LC Class. No.: R856 / .A474 2017
Dewey Class. No.: 610.28
Amperometric and impedance monitoring systems for biomedical applications
LDR
:03064nmm a2200301 a 4500
001
522428
003
DE-He213
005
20180327152719.0
006
m d
007
cr nn 008maaau
008
180521s2017 gw s 0 eng d
020
$a
9783319648019$q(electronic bk.)
020
$a
9783319648002$q(paper)
024
7
$a
10.1007/978-3-319-64801-9
$2
doi
035
$a
978-3-319-64801-9
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
R856
$b
.A474 2017
082
0 4
$a
610.28
$2
23
090
$a
R856
$b
.A526 2017
245
0 0
$a
Amperometric and impedance monitoring systems for biomedical applications
$h
[electronic resource] /
$c
by Jaime Punter-Villagrasa ... [et al.].
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2017.
300
$a
viii, 241 p. :
$b
ill., digital ;
$c
24 cm.
490
1
$a
Bioanalysis, advanced materials, methods, and devices,
$x
2364-1118 ;
$v
v.4
505
0
$a
Acknowledgements -- Abstract -- Abbreviations -- Contents -- List Of Figures -- 1 Introduction -- 2 Electronics architectures Box -- 3 Design, Test and Validation of the proposed Architecture -- 4 Validation of the Pervasive Architecture with different applications -- 5 New Generation of POC Device: AN Hematrocrit (HCT) Detection Case -- 6 Conclusions -- Appendix A: Schematics, Design and Validation of Different Potentiostat Topologies -- Appendix B: Schematics, Design and Validation of an Electronic Device for EIS Applications -- Appendix C: Schematics, Design and Validation of the HCT POC Device.
520
$a
The book presents the conception and realization of a pervasive electronic architecture for electrochemical applications, focusing on electronic instrumentation design and device development, particularly in electrochemical Point-of-Care and Lab-on-a-Chip devices, covering examples based on amperometric (DC) and impedance detection (AC) techniques. The presented electronics combine tailored front-end instrumentation and back-end data post-processing, enabling applications in different areas, and across a variety of techniques, analytes, transducers and environments. It addresses how the electronics are designed and implemented with special interest in the flow process: starting from electronic circuits and electrochemical biosensor design to a final validation and implementation for specific applications. Similarly, other important aspects are discussed throughout the book, such as electrochemical techniques, different analytes, targets, electronics reliability and robustness. The book also describes the use of the presented electronics in different electrochemical applications through some examples: instantaneous and non-destructive cellular monitoring and portable glucose monitoring device. Moreover, the book aims to introduce a comprehensive approach to electronic circuits, techniques and electrochemical sensors in POC devices to a general audience of students in biomedical and electronics engineering, scientists, and engineers.
650
0
$a
Biomedical engineering.
$3
190330
650
0
$a
Conductometric analysis.
$3
703686
650
0
$a
Systems on a chip.
$3
224012
650
1 4
$a
Physics.
$3
179414
650
2 4
$a
Medical and Radiation Physics.
$3
511317
650
2 4
$a
Circuits and Systems.
$3
274416
650
2 4
$a
Measurement Science and Instrumentation.
$3
376366
650
2 4
$a
Biomedical Engineering/Biotechnology.
$3
730838
650
2 4
$a
Electrochemistry.
$3
192934
700
1
$a
Punter-Villagrasa, Jaime.
$3
793077
710
2
$a
SpringerLink (Online service)
$3
273601
773
0
$t
Springer eBooks
830
0
$a
Bioanalysis, advanced materials, methods, and devices ;
$v
1.
$3
559348
856
4 0
$u
http://dx.doi.org/10.1007/978-3-319-64801-9
950
$a
Physics and Astronomy (Springer-11651)
based on 0 review(s)
ALL
電子館藏
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
000000147400
電子館藏
1圖書
電子書
EB R856 A526 2017
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Multimedia file
http://dx.doi.org/10.1007/978-3-319-64801-9
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login