語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Luminosity measurement at the compac...
~
Karacheban, Olena.
Luminosity measurement at the compact Muon solenoid experiment of the LHC
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Luminosity measurement at the compact Muon solenoid experiment of the LHCby Olena Karacheban.
作者:
Karacheban, Olena.
出版者:
Cham :Springer International Publishing :2018.
面頁冊數:
xvi, 142 p. :ill. (some col.), digital ;24 cm.
Contained By:
Springer eBooks
標題:
Luminescence spectroscopy.
電子資源:
http://dx.doi.org/10.1007/978-3-319-93139-5
ISBN:
9783319931395$q(electronic bk.)
Luminosity measurement at the compact Muon solenoid experiment of the LHC
Karacheban, Olena.
Luminosity measurement at the compact Muon solenoid experiment of the LHC
[electronic resource] /by Olena Karacheban. - Cham :Springer International Publishing :2018. - xvi, 142 p. :ill. (some col.), digital ;24 cm. - Springer theses,2190-5053. - Springer theses..
Introduction to Collider Physics -- Measurement of the Luminosity at Colliders -- BCM1F Detector as Luminometer -- Measurements of the Luminosity Using BCM1F -- Upgrade of the Luminometers for High Luminosity LHC.
This book describes the application of a novel technology for beam instrumentation and luminosity measurement and first results on a cutting edge technology potentially to be used after the upgrade of the Large Hadron Collider to higher luminosity. It presents a unique diamond-based luminometer with a detailed performance study. The online bunch-by-bunch luminosity measurements made provide an invaluable feedback to the Collider for beam optimisation and the understanding of the beam dynamics. The precision of the luminosity measurement is crucial for all physics analyses. This book highlights the Van der Meer method, which is used for the calibration of the luminometers of the CMS (Compact Muon Solenoid) experiment, and describes the estimate of systematic uncertainties, e.g. due to radiation damage of sensors and electronics and uncertainties of beam parameters. For the future high-luminosity upgrade of the collider, sapphire sensors are investigated in a test beam. It is demonstrated for the first time that sapphire sensors can be used as single particle detectors. A model for the charge transport in sapphire is developed and successfully applied.
ISBN: 9783319931395$q(electronic bk.)
Standard No.: 10.1007/978-3-319-93139-5doiSubjects--Topical Terms:
193629
Luminescence spectroscopy.
LC Class. No.: QC476.6 / .K373 2018
Dewey Class. No.: 539.72114
Luminosity measurement at the compact Muon solenoid experiment of the LHC
LDR
:02402nmm a2200325 a 4500
001
540886
003
DE-He213
005
20190114093917.0
006
m d
007
cr nn 008maaau
008
190308s2018 gw s 0 eng d
020
$a
9783319931395$q(electronic bk.)
020
$a
9783319931388$q(paper)
024
7
$a
10.1007/978-3-319-93139-5
$2
doi
035
$a
978-3-319-93139-5
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
QC476.6
$b
.K373 2018
072
7
$a
PHP
$2
bicssc
072
7
$a
SCI051000
$2
bisacsh
082
0 4
$a
539.72114
$2
23
090
$a
QC476.6
$b
.K18 2018
100
1
$a
Karacheban, Olena.
$3
819409
245
1 0
$a
Luminosity measurement at the compact Muon solenoid experiment of the LHC
$h
[electronic resource] /
$c
by Olena Karacheban.
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2018.
300
$a
xvi, 142 p. :
$b
ill. (some col.), digital ;
$c
24 cm.
490
1
$a
Springer theses,
$x
2190-5053
505
0
$a
Introduction to Collider Physics -- Measurement of the Luminosity at Colliders -- BCM1F Detector as Luminometer -- Measurements of the Luminosity Using BCM1F -- Upgrade of the Luminometers for High Luminosity LHC.
520
$a
This book describes the application of a novel technology for beam instrumentation and luminosity measurement and first results on a cutting edge technology potentially to be used after the upgrade of the Large Hadron Collider to higher luminosity. It presents a unique diamond-based luminometer with a detailed performance study. The online bunch-by-bunch luminosity measurements made provide an invaluable feedback to the Collider for beam optimisation and the understanding of the beam dynamics. The precision of the luminosity measurement is crucial for all physics analyses. This book highlights the Van der Meer method, which is used for the calibration of the luminometers of the CMS (Compact Muon Solenoid) experiment, and describes the estimate of systematic uncertainties, e.g. due to radiation damage of sensors and electronics and uncertainties of beam parameters. For the future high-luminosity upgrade of the collider, sapphire sensors are investigated in a test beam. It is demonstrated for the first time that sapphire sensors can be used as single particle detectors. A model for the charge transport in sapphire is developed and successfully applied.
650
0
$a
Luminescence spectroscopy.
$3
193629
650
0
$a
Muons
$x
Spectra.
$3
819410
650
1 4
$a
Physics.
$3
179414
650
2 4
$a
Particle Acceleration and Detection, Beam Physics.
$3
275493
650
2 4
$a
Measurement Science and Instrumentation.
$3
376366
710
2
$a
SpringerLink (Online service)
$3
273601
773
0
$t
Springer eBooks
830
0
$a
Springer theses.
$3
557607
856
4 0
$u
http://dx.doi.org/10.1007/978-3-319-93139-5
950
$a
Physics and Astronomy (Springer-11651)
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000160643
電子館藏
1圖書
電子書
EB QC476.6 K18 2018 2018
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://dx.doi.org/10.1007/978-3-319-93139-5
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入