語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Wireless power transfer and data com...
~
Dehollain, Catherine.
Wireless power transfer and data communication for intracranial neural recording applications
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Wireless power transfer and data communication for intracranial neural recording applicationsby Kerim Ture, Catherine Dehollain, Franco Maloberti.
作者:
Ture, Kerim.
其他作者:
Dehollain, Catherine.
出版者:
Cham :Springer International Publishing :2020.
面頁冊數:
xii, 112 p. :ill., digital ;24 cm.
Contained By:
Springer eBooks
標題:
Wireless power transmission.
電子資源:
https://doi.org/10.1007/978-3-030-40826-8
ISBN:
9783030408268$q(electronic bk.)
Wireless power transfer and data communication for intracranial neural recording applications
Ture, Kerim.
Wireless power transfer and data communication for intracranial neural recording applications
[electronic resource] /by Kerim Ture, Catherine Dehollain, Franco Maloberti. - Cham :Springer International Publishing :2020. - xii, 112 p. :ill., digital ;24 cm. - Analog circuits and signal processing,1872-082X. - Analog circuits and signal processing..
Chapter 1. Introduction -- Chapter 2. Implantable Monitoring System for Epilepsy -- Chapter 3. Powering of the Implanted Monitoring System -- Chapter 4. Wireless Data Communication -- Chapter 5. Experimental Validations -- Chapter 6. Conclusion.
This book describes new circuits and systems for implantable wireless neural monitoring systems and explains the design of a batteryless, remotely-powered implantable micro-system, designed for continuous neural monitoring. Following new trends in implantable biomedical applications, the authors demonstrate a system which is capable of efficient remote powering and reliable data communication. Novel architecture and design methodologies are used for low power and small area wireless communication link. Additionally, hermetically sealed packaging and in-vivo validation of the implantable device is presented. Provides up-to-date summaries of remote powering and wireless communication methods; Describes methods for improving the efficiency of remote powering and wireless communication; Includes a new topology for an energy and area efficiency ultrawideband transmitter; Provides in-vivo validation of the proposed circuits.
ISBN: 9783030408268$q(electronic bk.)
Standard No.: 10.1007/978-3-030-40826-8doiSubjects--Topical Terms:
762765
Wireless power transmission.
LC Class. No.: TK3088 / .T865 2020
Dewey Class. No.: 621.319
Wireless power transfer and data communication for intracranial neural recording applications
LDR
:02275nmm a2200337 a 4500
001
572605
003
DE-He213
005
20200803151501.0
006
m d
007
cr nn 008maaau
008
200925s2020 sz s 0 eng d
020
$a
9783030408268$q(electronic bk.)
020
$a
9783030408251$q(paper)
024
7
$a
10.1007/978-3-030-40826-8
$2
doi
035
$a
978-3-030-40826-8
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
TK3088
$b
.T865 2020
072
7
$a
TJFC
$2
bicssc
072
7
$a
TEC008010
$2
bisacsh
072
7
$a
TJFC
$2
thema
082
0 4
$a
621.319
$2
23
090
$a
TK3088
$b
.T934 2020
100
1
$a
Ture, Kerim.
$3
859733
245
1 0
$a
Wireless power transfer and data communication for intracranial neural recording applications
$h
[electronic resource] /
$c
by Kerim Ture, Catherine Dehollain, Franco Maloberti.
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2020.
300
$a
xii, 112 p. :
$b
ill., digital ;
$c
24 cm.
490
1
$a
Analog circuits and signal processing,
$x
1872-082X
505
0
$a
Chapter 1. Introduction -- Chapter 2. Implantable Monitoring System for Epilepsy -- Chapter 3. Powering of the Implanted Monitoring System -- Chapter 4. Wireless Data Communication -- Chapter 5. Experimental Validations -- Chapter 6. Conclusion.
520
$a
This book describes new circuits and systems for implantable wireless neural monitoring systems and explains the design of a batteryless, remotely-powered implantable micro-system, designed for continuous neural monitoring. Following new trends in implantable biomedical applications, the authors demonstrate a system which is capable of efficient remote powering and reliable data communication. Novel architecture and design methodologies are used for low power and small area wireless communication link. Additionally, hermetically sealed packaging and in-vivo validation of the implantable device is presented. Provides up-to-date summaries of remote powering and wireless communication methods; Describes methods for improving the efficiency of remote powering and wireless communication; Includes a new topology for an energy and area efficiency ultrawideband transmitter; Provides in-vivo validation of the proposed circuits.
650
0
$a
Wireless power transmission.
$3
762765
650
0
$a
Epilepsy
$x
Treatment.
$3
578573
650
0
$a
Implants, Artificial.
$3
303389
650
1 4
$a
Circuits and Systems.
$3
274416
650
2 4
$a
Cyber-physical systems, IoT.
$3
836359
650
2 4
$a
Electronics and Microelectronics, Instrumentation.
$3
274412
700
1
$a
Dehollain, Catherine.
$3
737687
700
1
$a
Maloberti, Franco.
$3
737688
710
2
$a
SpringerLink (Online service)
$3
273601
773
0
$t
Springer eBooks
830
0
$a
Analog circuits and signal processing.
$3
558088
856
4 0
$u
https://doi.org/10.1007/978-3-030-40826-8
950
$a
Engineering (Springer-11647)
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000179216
電子館藏
1圖書
電子書
EB TK3088 .T934 2020 2020
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
https://doi.org/10.1007/978-3-030-40826-8
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入