Electrical design of a 400 kV compos...
~
Jahangiri, Tohid.
Electrical design of a 400 kV composite tower
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Electrical design of a 400 kV composite towerby Tohid Jahangiri ... [et al.].
其他作者:
Jahangiri, Tohid.
出版者:
Cham :Springer International Publishing :2020.
面頁冊數:
xi, 249 p. :ill., digital ;24 cm.
Contained By:
Springer eBooks
標題:
Electric linesPoles and towers
電子資源:
https://doi.org/10.1007/978-3-030-17843-7
ISBN:
9783030178437$q(electronic bk.)
Electrical design of a 400 kV composite tower
Electrical design of a 400 kV composite tower
[electronic resource] /by Tohid Jahangiri ... [et al.]. - Cham :Springer International Publishing :2020. - xi, 249 p. :ill., digital ;24 cm. - Lecture notes in electrical engineering,v.5571876-1100 ;. - Lecture notes in electrical engineering ;v.132..
Introduction -- Fiber Reinforced Plasctic (FRP) composite selection for the composite cross-arm core -- Air clearances of fully composite pylon -- Electrical design of fully composite pylon -- Electric field verification by high voltage experiments on the composite cross-arm -- Lightning shielding performance of fully composite pylon -- Lightning shielding failure investigation by high voltage experiments -- Environmental effects of fully composite pylon.
This book presents an innovative concept for designing a 400 kV double circuit composite tower. The major challenges encountered by the authors in the electrical design process of the composite tower are addressed. They concern material selection for the full composite cross-arm core, electrical insulation of the cross-arm, electrical dimensioning of the full composite tower, lightning shielding performance and failure of the full composite tower. The electric field performance of the tower's insulation has been investigated theoretically by using finite element method and experimentally by testing different fiber reinforced polymers as candidates. The book reports in detail those finite element simulations and tests, together with the authors' recommendations on the most suitable materials and manufacturing process as well as conductor clamp designs for the cross-arm. Another important issue of the full composite tower, which concerns the environmental aspects of the full composite tower, has also been evaluated. This book offers a timely reference guide on a highly innovative topic, addressing researchers working on power transmission system both in industry and academia.
ISBN: 9783030178437$q(electronic bk.)
Standard No.: 10.1007/978-3-030-17843-7doiSubjects--Topical Terms:
222633
Electric lines
--Poles and towers
LC Class. No.: TK3242
Dewey Class. No.: 621.31922
Electrical design of a 400 kV composite tower
LDR
:02678nmm a2200337 a 4500
001
577984
003
DE-He213
005
20200210090006.0
006
m d
007
cr nn 008maaau
008
201208s2020 sz s 0 eng d
020
$a
9783030178437$q(electronic bk.)
020
$a
9783030178420$q(paper)
024
7
$a
10.1007/978-3-030-17843-7
$2
doi
035
$a
978-3-030-17843-7
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
TK3242
072
7
$a
THRD
$2
bicssc
072
7
$a
TEC046000
$2
bisacsh
072
7
$a
THR
$2
thema
082
0 4
$a
621.31922
$2
23
090
$a
TK3242
$b
.E38 2020
245
0 0
$a
Electrical design of a 400 kV composite tower
$h
[electronic resource] /
$c
by Tohid Jahangiri ... [et al.].
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2020.
300
$a
xi, 249 p. :
$b
ill., digital ;
$c
24 cm.
490
1
$a
Lecture notes in electrical engineering,
$x
1876-1100 ;
$v
v.557
505
0
$a
Introduction -- Fiber Reinforced Plasctic (FRP) composite selection for the composite cross-arm core -- Air clearances of fully composite pylon -- Electrical design of fully composite pylon -- Electric field verification by high voltage experiments on the composite cross-arm -- Lightning shielding performance of fully composite pylon -- Lightning shielding failure investigation by high voltage experiments -- Environmental effects of fully composite pylon.
520
$a
This book presents an innovative concept for designing a 400 kV double circuit composite tower. The major challenges encountered by the authors in the electrical design process of the composite tower are addressed. They concern material selection for the full composite cross-arm core, electrical insulation of the cross-arm, electrical dimensioning of the full composite tower, lightning shielding performance and failure of the full composite tower. The electric field performance of the tower's insulation has been investigated theoretically by using finite element method and experimentally by testing different fiber reinforced polymers as candidates. The book reports in detail those finite element simulations and tests, together with the authors' recommendations on the most suitable materials and manufacturing process as well as conductor clamp designs for the cross-arm. Another important issue of the full composite tower, which concerns the environmental aspects of the full composite tower, has also been evaluated. This book offers a timely reference guide on a highly innovative topic, addressing researchers working on power transmission system both in industry and academia.
650
0
$a
Electric lines
$x
Poles and towers
$x
Design and construction.
$3
222633
650
1 4
$a
Power Electronics, Electrical Machines and Networks.
$3
338660
650
2 4
$a
Energy Systems.
$3
512090
650
2 4
$a
Ceramics, Glass, Composites, Natural Materials.
$3
764200
700
1
$a
Jahangiri, Tohid.
$3
866603
710
2
$a
SpringerLink (Online service)
$3
273601
773
0
$t
Springer eBooks
830
0
$a
Lecture notes in electrical engineering ;
$v
v.132.
$3
545003
856
4 0
$u
https://doi.org/10.1007/978-3-030-17843-7
950
$a
Engineering (Springer-11647)
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000182882
電子館藏
1圖書
電子書
EB TK3242 .E38 2020 2020
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
https://doi.org/10.1007/978-3-030-17843-7
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入