語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Development of 15 micron cutoff wave...
~
Cabrera, Mario.
Development of 15 micron cutoff wavelength HgCdTe detector arrays for astronomy
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Development of 15 micron cutoff wavelength HgCdTe detector arrays for astronomyby Mario Cabrera.
作者:
Cabrera, Mario.
出版者:
Cham :Springer International Publishing :2020.
面頁冊數:
xvii, 121 p. :ill., digital ;24 cm.
Contained By:
Springer Nature eBook
標題:
Infrared array detectors.
電子資源:
https://doi.org/10.1007/978-3-030-54241-2
ISBN:
9783030542412$q(electronic bk.)
Development of 15 micron cutoff wavelength HgCdTe detector arrays for astronomy
Cabrera, Mario.
Development of 15 micron cutoff wavelength HgCdTe detector arrays for astronomy
[electronic resource] /by Mario Cabrera. - Cham :Springer International Publishing :2020. - xvii, 121 p. :ill., digital ;24 cm. - Springer theses,2190-5053. - Springer theses..
Chapter1: Introduction -- Chapter2: Test and Data Acquisition Setup -- Chapter3: Dark Current Theory -- Chapter4: Array Characterization -- Chapter5: Phase I Results: 13 m Cuto Wavelength Devices -- Chapter6: Phase II Results: 15 m Cuto Wavelength Devices -- Chapter7: Conclusions and Future Work.
This thesis describes advances in the understanding of HgCdTe detectors. While long wave (15 um) infrared detectors HgCdTe detectors have been developed for military use under high background irradiance, these arrays had not previously been developed for astronomical use where the background irradiance is a billion times smaller. The main pitfall in developing such arrays for astronomy is the pixel dark current which plagues long wave HgCdTe. The author details work on the success of shorter wavelength development at Teledyne Imaging Sensors, carefully modeling the dark current-reverse bias voltage curves of their 10 um devices at a temperature of 30K, as well as the dark current-temperature curves at several reverse biases, including 250 mV. By projecting first to 13 and then 15 um HgCdTe growth, values of fundamental properties of the material that would minimize tunneling dark currents were determined through careful modeling of the dark current-reverse bias voltage curves, as well as the dark current-temperature curves. This analysis was borne out in the 13 um parts produced by Teledyne, and then further honed to produce the necessary parameters for the 15 um growth. The resulting 13 um arrays are being considered by a number of ground-based astronomy research groups.
ISBN: 9783030542412$q(electronic bk.)
Standard No.: 10.1007/978-3-030-54241-2doiSubjects--Topical Terms:
753808
Infrared array detectors.
LC Class. No.: TA1570
Dewey Class. No.: 621.362
Development of 15 micron cutoff wavelength HgCdTe detector arrays for astronomy
LDR
:02622nmm a2200337 a 4500
001
586332
003
DE-He213
005
20210129151015.0
006
m d
007
cr nn 008maaau
008
210323s2020 sz s 0 eng d
020
$a
9783030542412$q(electronic bk.)
020
$a
9783030542405$q(paper)
024
7
$a
10.1007/978-3-030-54241-2
$2
doi
035
$a
978-3-030-54241-2
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
TA1570
072
7
$a
PG
$2
bicssc
072
7
$a
SCI004000
$2
bisacsh
072
7
$a
PG
$2
thema
082
0 4
$a
621.362
$2
23
090
$a
TA1570
$b
.C117 2020
100
1
$a
Cabrera, Mario.
$3
877746
245
1 0
$a
Development of 15 micron cutoff wavelength HgCdTe detector arrays for astronomy
$h
[electronic resource] /
$c
by Mario Cabrera.
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2020.
300
$a
xvii, 121 p. :
$b
ill., digital ;
$c
24 cm.
490
1
$a
Springer theses,
$x
2190-5053
505
0
$a
Chapter1: Introduction -- Chapter2: Test and Data Acquisition Setup -- Chapter3: Dark Current Theory -- Chapter4: Array Characterization -- Chapter5: Phase I Results: 13 m Cuto Wavelength Devices -- Chapter6: Phase II Results: 15 m Cuto Wavelength Devices -- Chapter7: Conclusions and Future Work.
520
$a
This thesis describes advances in the understanding of HgCdTe detectors. While long wave (15 um) infrared detectors HgCdTe detectors have been developed for military use under high background irradiance, these arrays had not previously been developed for astronomical use where the background irradiance is a billion times smaller. The main pitfall in developing such arrays for astronomy is the pixel dark current which plagues long wave HgCdTe. The author details work on the success of shorter wavelength development at Teledyne Imaging Sensors, carefully modeling the dark current-reverse bias voltage curves of their 10 um devices at a temperature of 30K, as well as the dark current-temperature curves at several reverse biases, including 250 mV. By projecting first to 13 and then 15 um HgCdTe growth, values of fundamental properties of the material that would minimize tunneling dark currents were determined through careful modeling of the dark current-reverse bias voltage curves, as well as the dark current-temperature curves. This analysis was borne out in the 13 um parts produced by Teledyne, and then further honed to produce the necessary parameters for the 15 um growth. The resulting 13 um arrays are being considered by a number of ground-based astronomy research groups.
650
0
$a
Infrared array detectors.
$3
753808
650
1 4
$a
Astronomy, Observations and Techniques.
$3
376735
650
2 4
$a
Measurement Science and Instrumentation.
$3
376366
650
2 4
$a
Materials Science, general.
$3
308687
650
2 4
$a
Semiconductors.
$3
182134
710
2
$a
SpringerLink (Online service)
$3
273601
773
0
$t
Springer Nature eBook
830
0
$a
Springer theses.
$3
557607
856
4 0
$u
https://doi.org/10.1007/978-3-030-54241-2
950
$a
Physics and Astronomy (SpringerNature-11651)
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000190152
電子館藏
1圖書
電子書
EB TA1570 .C117 2020 2020
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
https://doi.org/10.1007/978-3-030-54241-2
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入