語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Model fire in a two-storey timber bu...
~
SpringerLink (Online service)
Model fire in a two-storey timber building
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Model fire in a two-storey timber buildingby Jozef Stefko ... [et al.].
其他作者:
Stefko, Jozef.
出版者:
Cham :Springer International Publishing :2021.
面頁冊數:
xxiii, 82 p. :ill. (some col.), digital ;24 cm.
Contained By:
Springer Nature eBook
標題:
Fire testing.
電子資源:
https://doi.org/10.1007/978-3-030-82205-7
ISBN:
9783030822057$q(electronic bk.)
Model fire in a two-storey timber building
Model fire in a two-storey timber building
[electronic resource] /by Jozef Stefko ... [et al.]. - Cham :Springer International Publishing :2021. - xxiii, 82 p. :ill. (some col.), digital ;24 cm. - SpringerBriefs in fire,2193-6595. - SpringerBriefs in fire..
Preface -- Foreword -- List of Symbols -- 1.0 A Building and a Fire -- 2.0 Wood - a Combustible Building Material -- 2.1 General Characteristics of Wood -- 2.2 Wood Degradation by Heat Impact (By Fire) -- 2.2.1 Thermal Degradation of Main Wood Components -- 2.2.2 Wood Microscopic Structure Changes by High-Temperature Stress -- 2.2.3 Wood Macroscopic Structure Changes by High-Temperature Stress -- 2.2.4 Physical Properties of Thermally Degraded Wood -- 2.2.5 Mechanical Properties of Thermally Degraded Wood -- 2.2.5.1 Temperature Impact to Bending Strength and to Bending Modulus of Elasticity -- 2.2.5.2 Temperature Impact to Tension Strength and MOE at Tension Parallel to Grain -- 2.2.5.3 Temperature Impact to Wood Compression Properties Parallel to Grain -- 2.2.5.4 Temperature Effect on Shear Strength of Wood -- 2.2.5.5 Charring Rate Effect to Mechanical Properties of Wood in General -- 2.3 Fire Resistance of Wooden Structures -- 2.4 Eurocode 5 -- 2.4.1 Origin and Development of Eurocode Standards Programme -- 2.4.2 Related European Standards -- 2.4.3 Design Principles -- 2.4.4. Examples -- 2.5 Conclusion -- 3.0 Full-Size Fire Test of a Wooden Structure -- 3.1 The Concept of the Full-Size Tests -- 3.2 Structural Fire Test Scheme of Two-Storey Building -- 3.3 Construction Process of the Fire-Tested Two-Storey Building -- 3.4 Photos of the Test Structural Fire -- 3.5 The Fire Assessment -- 3.5.1 The Fire Assessment - Ground Floor -- 3.5.2 The Fire Assessment - First Floor -- 3.5.3 The Temperature Assessment - the East External Wall -- 3.5.4 The Temperature Assessment - the West External Wall -- 3.5.5 The Temperature Assessment - the North External Wall -- 3.5.6 The Temperature Assessment - the South External Wall -- 4.0 Summary of the Experiment.
This book addresses the performance of a multi-storey timber building subjected to a model fire that represents a real, potentially devastating internal fire. Readers will learn about factors concerning fire hazards in buildings; the mechanisms of how fires start and spread; and the degrading impact of fire on wood and wood-based materials, especially their mechanical properties. The book also discusses the fire resistance of timber buildings and the design principles for fire safety, summarised in Eurocodes. In turn, a fire test on a full-size wooden structure demonstrates the principles discussed. The test makes up an essential part of the book, as to its individual steps: the development, planning, execution and subsequent assessment. This is complemented by detailed temperature monitoring at hundreds of individual spots and the reaction of the wood constructions, illustrated in extensive photo documentation. The temperature and fire development presented there show the fire's initial mechanism and its further behaviour in a wood construction. The test proved the feasibility of fire protection and safe design of timber buildings, offering insights that can be generally applied in research, material and construction development. Accordingly, the book will be especially useful for architects, building and fire engineers, as well as researchers dealing with the fire performance of timber buildings.
ISBN: 9783030822057$q(electronic bk.)
Standard No.: 10.1007/978-3-030-82205-7doiSubjects--Topical Terms:
681310
Fire testing.
LC Class. No.: TH1091
Dewey Class. No.: 628.92
Model fire in a two-storey timber building
LDR
:04219nmm a2200337 a 4500
001
605303
003
DE-He213
005
20210804120151.0
006
m d
007
cr nn 008maaau
008
211201s2021 sz s 0 eng d
020
$a
9783030822057$q(electronic bk.)
020
$a
9783030822040$q(paper)
024
7
$a
10.1007/978-3-030-82205-7
$2
doi
035
$a
978-3-030-82205-7
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
TH1091
072
7
$a
TNKF
$2
bicssc
072
7
$a
TEC045000
$2
bisacsh
072
7
$a
TNKF
$2
thema
082
0 4
$a
628.92
$2
23
090
$a
TH1091
$b
.M689 2021
245
0 0
$a
Model fire in a two-storey timber building
$h
[electronic resource] /
$c
by Jozef Stefko ... [et al.].
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2021.
300
$a
xxiii, 82 p. :
$b
ill. (some col.), digital ;
$c
24 cm.
490
1
$a
SpringerBriefs in fire,
$x
2193-6595
505
0
$a
Preface -- Foreword -- List of Symbols -- 1.0 A Building and a Fire -- 2.0 Wood - a Combustible Building Material -- 2.1 General Characteristics of Wood -- 2.2 Wood Degradation by Heat Impact (By Fire) -- 2.2.1 Thermal Degradation of Main Wood Components -- 2.2.2 Wood Microscopic Structure Changes by High-Temperature Stress -- 2.2.3 Wood Macroscopic Structure Changes by High-Temperature Stress -- 2.2.4 Physical Properties of Thermally Degraded Wood -- 2.2.5 Mechanical Properties of Thermally Degraded Wood -- 2.2.5.1 Temperature Impact to Bending Strength and to Bending Modulus of Elasticity -- 2.2.5.2 Temperature Impact to Tension Strength and MOE at Tension Parallel to Grain -- 2.2.5.3 Temperature Impact to Wood Compression Properties Parallel to Grain -- 2.2.5.4 Temperature Effect on Shear Strength of Wood -- 2.2.5.5 Charring Rate Effect to Mechanical Properties of Wood in General -- 2.3 Fire Resistance of Wooden Structures -- 2.4 Eurocode 5 -- 2.4.1 Origin and Development of Eurocode Standards Programme -- 2.4.2 Related European Standards -- 2.4.3 Design Principles -- 2.4.4. Examples -- 2.5 Conclusion -- 3.0 Full-Size Fire Test of a Wooden Structure -- 3.1 The Concept of the Full-Size Tests -- 3.2 Structural Fire Test Scheme of Two-Storey Building -- 3.3 Construction Process of the Fire-Tested Two-Storey Building -- 3.4 Photos of the Test Structural Fire -- 3.5 The Fire Assessment -- 3.5.1 The Fire Assessment - Ground Floor -- 3.5.2 The Fire Assessment - First Floor -- 3.5.3 The Temperature Assessment - the East External Wall -- 3.5.4 The Temperature Assessment - the West External Wall -- 3.5.5 The Temperature Assessment - the North External Wall -- 3.5.6 The Temperature Assessment - the South External Wall -- 4.0 Summary of the Experiment.
520
$a
This book addresses the performance of a multi-storey timber building subjected to a model fire that represents a real, potentially devastating internal fire. Readers will learn about factors concerning fire hazards in buildings; the mechanisms of how fires start and spread; and the degrading impact of fire on wood and wood-based materials, especially their mechanical properties. The book also discusses the fire resistance of timber buildings and the design principles for fire safety, summarised in Eurocodes. In turn, a fire test on a full-size wooden structure demonstrates the principles discussed. The test makes up an essential part of the book, as to its individual steps: the development, planning, execution and subsequent assessment. This is complemented by detailed temperature monitoring at hundreds of individual spots and the reaction of the wood constructions, illustrated in extensive photo documentation. The temperature and fire development presented there show the fire's initial mechanism and its further behaviour in a wood construction. The test proved the feasibility of fire protection and safe design of timber buildings, offering insights that can be generally applied in research, material and construction development. Accordingly, the book will be especially useful for architects, building and fire engineers, as well as researchers dealing with the fire performance of timber buildings.
650
0
$a
Fire testing.
$3
681310
650
0
$a
Fires
$v
Case studies.
$3
901375
650
1 4
$a
Fire Science, Hazard Control, Building Safety.
$3
772186
650
2 4
$a
Building Construction and Design.
$3
761394
650
2 4
$a
Light Construction, Steel Construction, Timber Construction.
$3
712947
650
2 4
$a
Structural Materials.
$3
274623
700
1
$a
Stefko, Jozef.
$3
901374
710
2
$a
SpringerLink (Online service)
$3
273601
773
0
$t
Springer Nature eBook
830
0
$a
SpringerBriefs in fire.
$3
549758
856
4 0
$u
https://doi.org/10.1007/978-3-030-82205-7
950
$a
Computer Science (SpringerNature-11645)
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000203350
電子館藏
1圖書
電子書
EB TH1091 .M689 2021 2021
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
https://doi.org/10.1007/978-3-030-82205-7
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入