語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Coherent array imaging using phased subarrays.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Coherent array imaging using phased subarrays.
作者:
Johnson, Jeremy Aaron.
面頁冊數:
198 p.
附註:
Adviser: Ramin Shahidi.
附註:
Source: Dissertation Abstracts International, Volume: 64-09, Section: B, page: 4525.
Contained By:
Dissertation Abstracts International64-09B.
標題:
Engineering, Electronics and Electrical.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3104255
ISBN:
0496518232
Coherent array imaging using phased subarrays.
Johnson, Jeremy Aaron.
Coherent array imaging using phased subarrays.
[electronic resource] - 198 p.
Adviser: Ramin Shahidi.
Thesis (Ph.D.)--Stanford University, 2003.
PSA and FPA imaging are compared using experimental data for 2D imaging and simulated data for 3D imaging. Experimental images were formed of a wire phantom using a 128-element capacitive micromachined ultrasound transducer array. PSA imaging had little or no affect on the axial resolution and little or no effect on the lateral resolution within the focal region. The SNR of the PSA images was slightly lower than that of the FPA images when using 32-element subarrays, and decreased for smaller subarrays. The contrast-to-noise ratio of PSA and FPA imaging was compared using simulated pulse-echo data of a cyst phantom and was slightly lower for all PSA imaging methods. The results illustrate that PSA imaging reduces the front-end hardware complexity and can enable real-time 3D ultrasound imaging.
ISBN: 0496518232Subjects--Topical Terms:
226981
Engineering, Electronics and Electrical.
Coherent array imaging using phased subarrays.
LDR
:03067nmm _2200289 _450
001
162179
005
20051017073419.5
008
230606s2003 eng d
020
$a
0496518232
035
$a
00148680
035
$a
162179
040
$a
UnM
$c
UnM
100
0
$a
Johnson, Jeremy Aaron.
$3
227296
245
1 0
$a
Coherent array imaging using phased subarrays.
$h
[electronic resource]
300
$a
198 p.
500
$a
Adviser: Ramin Shahidi.
500
$a
Source: Dissertation Abstracts International, Volume: 64-09, Section: B, page: 4525.
502
$a
Thesis (Ph.D.)--Stanford University, 2003.
520
#
$a
PSA and FPA imaging are compared using experimental data for 2D imaging and simulated data for 3D imaging. Experimental images were formed of a wire phantom using a 128-element capacitive micromachined ultrasound transducer array. PSA imaging had little or no affect on the axial resolution and little or no effect on the lateral resolution within the focal region. The SNR of the PSA images was slightly lower than that of the FPA images when using 32-element subarrays, and decreased for smaller subarrays. The contrast-to-noise ratio of PSA and FPA imaging was compared using simulated pulse-echo data of a cyst phantom and was slightly lower for all PSA imaging methods. The results illustrate that PSA imaging reduces the front-end hardware complexity and can enable real-time 3D ultrasound imaging.
520
#
$a
Phased subarray (PSA) imaging has been proposed as a method to reduce the imaging system's front-end hardware complexity while achieving near-FPA image quality. Each scan line is formed using multiple subsets of adjacent elements---subarrays---that span the full array. PSA imaging reduces the number of front-end hardware channels to the number of elements in the subarray.
520
#
$a
This dissertation extends the capabilities of PSA imaging. A mathematical model of the imaging response in the spatial domain and spatial frequency domain, or k-space, is developed for PSA imaging. This model is used as the basis for two new methods of designing subarray reconstruction filters for wideband PSA imaging.
520
#
$a
This research was motivated by the need to reduce the front-end hardware complexity of 3D ultrasound imaging systems using 2D transducer arrays. The results apply to other coherent array imaging applications including sonar, radio astronomy, and seismic imaging. Conventional full phased array (FPA) imaging requires parallel front-end electronic hardware to process the signals from each element independently. While currently used for commercial 2D ultrasound imaging using 1D transducer arrays, FPA imaging does not scale well to 3D imaging due to the overwhelming number of transducer elements.
590
$a
School code: 0212.
650
# 0
$a
Engineering, Electronics and Electrical.
$3
226981
650
# 0
$a
Physics, Acoustics.
$3
227297
650
# 0
$a
Health Sciences, Radiology.
$3
227298
710
0 #
$a
Stanford University.
$3
212607
773
0 #
$g
64-09B.
$t
Dissertation Abstracts International
790
$a
0212
790
1 0
$a
Shahidi, Ramin,
$e
advisor
791
$a
Ph.D.
792
$a
2003
856
4 0
$u
http://libsw.nuk.edu.tw/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3104255
$z
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3104255
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000000672
電子館藏
1圖書
學位論文
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://libsw.nuk.edu.tw/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3104255
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入