語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Collimator-based tracking with an ad...
~
Bohler, Andreas.
Collimator-based tracking with an add-on multileaf collimatormodification of a commercial collimator system for realtime applications /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Collimator-based tracking with an add-on multileaf collimatorby Andreas Bohler.
其他題名:
modification of a commercial collimator system for realtime applications /
作者:
Bohler, Andreas.
出版者:
Wiesbaden :Springer Fachmedien Wiesbaden :2016.
面頁冊數:
xiv, 53 p. :ill., digital ;24 cm.
Contained By:
Springer eBooks
標題:
RadiotherapyEquipment and supplies.
電子資源:
http://dx.doi.org/10.1007/978-3-658-10658-4
ISBN:
9783658106584$q(electronic bk.)
Collimator-based tracking with an add-on multileaf collimatormodification of a commercial collimator system for realtime applications /
Bohler, Andreas.
Collimator-based tracking with an add-on multileaf collimator
modification of a commercial collimator system for realtime applications /[electronic resource] :by Andreas Bohler. - Wiesbaden :Springer Fachmedien Wiesbaden :2016. - xiv, 53 p. :ill., digital ;24 cm. - BestMedDiss. - BestMedDiss..
1 Introduction -- 2 Literature Overview -- 3 Hypothesis & Goals -- 4 Materials & Methods -- 5 Results -- 6 Discussion -- 7 Conclusions.
In this thesis, a tracking system was developed by modifying an add-on collimator, the Siemens Moduleaf, for realtime applications in radiotherapy. As the add-on collimator works almost completely autonomously of the linear accelerator (LinAc), no modifications to the latter were necessary. The adaptations to the Moduleaf were mainly software-based. In order to reduce the complexity of the system, outdated electronic parts were replaced with newer components where practical. Verification was performed by measuring the latency of the system as well as the impact on applied dose to a predefined target volume, moving in the leaf's travel direction. Latency measurements in software were accomplished by comparing the target and current positions of the leaves. For dose measurements, a Gafchromic EBT2 film was placed beneath the target 4D phantom, in between solid water plates, and moved alongside with it. Based on the results, a tracking-capable add-on collimator seems to be a useful tool for reducing the margins for the treatment of small, slow-moving targets. Radiotherapy is one of the most important methods used for the treatment of cancer. Irradiating a moving target is also one of the most challenging tasks to accomplish in modern radiotherapy.
ISBN: 9783658106584$q(electronic bk.)
Standard No.: 10.1007/978-3-658-10658-4doiSubjects--Topical Terms:
738227
Radiotherapy
--Equipment and supplies.
LC Class. No.: RM862.5
Dewey Class. No.: 615.842
Collimator-based tracking with an add-on multileaf collimatormodification of a commercial collimator system for realtime applications /
LDR
:02434nmm a2200325 a 4500
001
481886
003
DE-He213
005
20160727142611.0
006
m d
007
cr nn 008maaau
008
161007s2016 gw s 0 eng d
020
$a
9783658106584$q(electronic bk.)
020
$a
9783658106577$q(paper)
024
7
$a
10.1007/978-3-658-10658-4
$2
doi
035
$a
978-3-658-10658-4
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
RM862.5
072
7
$a
MJCL1
$2
bicssc
072
7
$a
MED080000
$2
bisacsh
082
0 4
$a
615.842
$2
23
090
$a
RM862.5
$b
.B676 2016
100
1
$a
Bohler, Andreas.
$3
738225
245
1 0
$a
Collimator-based tracking with an add-on multileaf collimator
$h
[electronic resource] :
$b
modification of a commercial collimator system for realtime applications /
$c
by Andreas Bohler.
260
$a
Wiesbaden :
$b
Springer Fachmedien Wiesbaden :
$b
Imprint: Springer,
$c
2016.
300
$a
xiv, 53 p. :
$b
ill., digital ;
$c
24 cm.
490
1
$a
BestMedDiss
505
0
$a
1 Introduction -- 2 Literature Overview -- 3 Hypothesis & Goals -- 4 Materials & Methods -- 5 Results -- 6 Discussion -- 7 Conclusions.
520
$a
In this thesis, a tracking system was developed by modifying an add-on collimator, the Siemens Moduleaf, for realtime applications in radiotherapy. As the add-on collimator works almost completely autonomously of the linear accelerator (LinAc), no modifications to the latter were necessary. The adaptations to the Moduleaf were mainly software-based. In order to reduce the complexity of the system, outdated electronic parts were replaced with newer components where practical. Verification was performed by measuring the latency of the system as well as the impact on applied dose to a predefined target volume, moving in the leaf's travel direction. Latency measurements in software were accomplished by comparing the target and current positions of the leaves. For dose measurements, a Gafchromic EBT2 film was placed beneath the target 4D phantom, in between solid water plates, and moved alongside with it. Based on the results, a tracking-capable add-on collimator seems to be a useful tool for reducing the margins for the treatment of small, slow-moving targets. Radiotherapy is one of the most important methods used for the treatment of cancer. Irradiating a moving target is also one of the most challenging tasks to accomplish in modern radiotherapy.
650
0
$a
Radiotherapy
$x
Equipment and supplies.
$3
738227
650
0
$a
Collimators (Optical instrument)
$3
738228
650
1 4
$a
Medicine & Public Health.
$3
273799
650
2 4
$a
Radiotherapy.
$3
274202
650
2 4
$a
Oncology.
$3
195181
710
2
$a
SpringerLink (Online service)
$3
273601
773
0
$t
Springer eBooks
830
0
$a
BestMedDiss.
$3
738226
856
4 0
$u
http://dx.doi.org/10.1007/978-3-658-10658-4
950
$a
Medicine (Springer-11650)
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000121723
電子館藏
1圖書
電子書
EB RM862.5 B676 2016
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://dx.doi.org/10.1007/978-3-658-10658-4
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入