語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Wind-Driven External Aerodynamics Ar...
~
Bettenhausen, Daniel W.
Wind-Driven External Aerodynamics Around Buildings and Buoyancy-Driven Fluid Motion and Heat Transfer in Internal Flow Passages.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Wind-Driven External Aerodynamics Around Buildings and Buoyancy-Driven Fluid Motion and Heat Transfer in Internal Flow Passages.
作者:
Bettenhausen, Daniel W.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, 2017
面頁冊數:
239 p.
附註:
Source: Dissertation Abstracts International, Volume: 79-02(E), Section: B.
附註:
Adviser: Ephraim M. Sparrow.
Contained By:
Dissertation Abstracts International79-02B(E).
標題:
Engineering.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10620888
ISBN:
9780355406191
Wind-Driven External Aerodynamics Around Buildings and Buoyancy-Driven Fluid Motion and Heat Transfer in Internal Flow Passages.
Bettenhausen, Daniel W.
Wind-Driven External Aerodynamics Around Buildings and Buoyancy-Driven Fluid Motion and Heat Transfer in Internal Flow Passages.
- Ann Arbor : ProQuest Dissertations & Theses, 2017 - 239 p.
Source: Dissertation Abstracts International, Volume: 79-02(E), Section: B.
Thesis (Ph.D.)--University of Minnesota, 2017.
Two areas of focus are considered with respect to the resilience of buildings to withstand environmental forces and to the enhancement of building energy efficiency. First, wind-driven pressure and velocity fields surrounding a model building are calculated by means of computational fluid dynamics (CFD) in two- and three- dimensions using the Shear Stress Transport (SST) turbulence model. The sensitivity of pressure coefficient distributions over each building surface to the placement of the solution domain and to the applied boundary conditions is determined. Pressure coefficient magnitudes were found to be particularly sensitive to the distance separating the upstream boundary of the solution domain, where the atmospheric boundary layer velocity profile is specified, from the location of the building. The magnitude of pressure coefficients at each building surface tended to decrease with increasing upstream distance of the applied velocity profile. At the building roof, the three-dimensional representation of the building resolved off-roof-centerline periodic transient pressure coefficient variations whereas the two-dimensional model predicted steady-state pressure coefficients over the entire rooftop. Building energy efficiency was studied via CFD to determine buoyancy-based heat transfer and velocity distributions in an asymmetrically heated vertical-wall channel representing a double-walled building with and without obstructions placed within the vertical channel. Specifically, catwalks consisting of an array of rectangular slats were deployed at two floor levels of a three-story building. The numerical model employed is validated by comparison with experimental data from a literature source. Channel Nusselt numbers and Reynolds numbers were found to increase with the openness of the catwalk elements to flow passage and also with the channel Rayleigh number. A porous-medium model employing the Darcy-Forchheimer equation is considered as a means to represent the pressure drop of each catwalk grating. This approach yielded results of only moderate accuracy for the velocity field because the porous-medium model does not faithfully reproduce turbulence. On the other hand, an approximation-free model was successfully employed to yield highly accurate fluid flow and heat transfer results for the channel flow.
ISBN: 9780355406191Subjects--Topical Terms:
210888
Engineering.
Wind-Driven External Aerodynamics Around Buildings and Buoyancy-Driven Fluid Motion and Heat Transfer in Internal Flow Passages.
LDR
:03370nmm a2200313 4500
001
523944
005
20180517120325.5
008
180709s2017 ||||||||||||||||| ||eng d
020
$a
9780355406191
035
$a
(MiAaPQ)AAI10620888
035
$a
(MiAaPQ)umn:18486
035
$a
AAI10620888
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Bettenhausen, Daniel W.
$3
795438
245
1 0
$a
Wind-Driven External Aerodynamics Around Buildings and Buoyancy-Driven Fluid Motion and Heat Transfer in Internal Flow Passages.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2017
300
$a
239 p.
500
$a
Source: Dissertation Abstracts International, Volume: 79-02(E), Section: B.
500
$a
Adviser: Ephraim M. Sparrow.
502
$a
Thesis (Ph.D.)--University of Minnesota, 2017.
520
$a
Two areas of focus are considered with respect to the resilience of buildings to withstand environmental forces and to the enhancement of building energy efficiency. First, wind-driven pressure and velocity fields surrounding a model building are calculated by means of computational fluid dynamics (CFD) in two- and three- dimensions using the Shear Stress Transport (SST) turbulence model. The sensitivity of pressure coefficient distributions over each building surface to the placement of the solution domain and to the applied boundary conditions is determined. Pressure coefficient magnitudes were found to be particularly sensitive to the distance separating the upstream boundary of the solution domain, where the atmospheric boundary layer velocity profile is specified, from the location of the building. The magnitude of pressure coefficients at each building surface tended to decrease with increasing upstream distance of the applied velocity profile. At the building roof, the three-dimensional representation of the building resolved off-roof-centerline periodic transient pressure coefficient variations whereas the two-dimensional model predicted steady-state pressure coefficients over the entire rooftop. Building energy efficiency was studied via CFD to determine buoyancy-based heat transfer and velocity distributions in an asymmetrically heated vertical-wall channel representing a double-walled building with and without obstructions placed within the vertical channel. Specifically, catwalks consisting of an array of rectangular slats were deployed at two floor levels of a three-story building. The numerical model employed is validated by comparison with experimental data from a literature source. Channel Nusselt numbers and Reynolds numbers were found to increase with the openness of the catwalk elements to flow passage and also with the channel Rayleigh number. A porous-medium model employing the Darcy-Forchheimer equation is considered as a means to represent the pressure drop of each catwalk grating. This approach yielded results of only moderate accuracy for the velocity field because the porous-medium model does not faithfully reproduce turbulence. On the other hand, an approximation-free model was successfully employed to yield highly accurate fluid flow and heat transfer results for the channel flow.
590
$a
School code: 0130.
650
4
$a
Engineering.
$3
210888
650
4
$a
Mechanical engineering.
$3
190348
650
4
$a
Mathematics.
$3
184409
690
$a
0537
690
$a
0548
690
$a
0405
710
2
$a
University of Minnesota.
$b
Mechanical Engineering.
$3
795439
773
0
$t
Dissertation Abstracts International
$g
79-02B(E).
790
$a
0130
791
$a
Ph.D.
792
$a
2017
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10620888
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000148195
電子館藏
1圖書
學位論文
TH 2017
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10620888
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入