語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Seismic Tensile Force on Steel Girde...
~
Hui, Yuchen.
Seismic Tensile Force on Steel Girder-Concrete Wall Connections in High-Rise Composite Building Structures.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Seismic Tensile Force on Steel Girder-Concrete Wall Connections in High-Rise Composite Building Structures.
作者:
Hui, Yuchen.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, 2018
面頁冊數:
125 p.
附註:
Source: Masters Abstracts International, Volume: 57-06.
附註:
Adviser: Jian Zhao.
Contained By:
Masters Abstracts International57-06(E).
標題:
Civil engineering.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10816167
ISBN:
9780438024625
Seismic Tensile Force on Steel Girder-Concrete Wall Connections in High-Rise Composite Building Structures.
Hui, Yuchen.
Seismic Tensile Force on Steel Girder-Concrete Wall Connections in High-Rise Composite Building Structures.
- Ann Arbor : ProQuest Dissertations & Theses, 2018 - 125 p.
Source: Masters Abstracts International, Volume: 57-06.
Thesis (M.S.)--The University of Wisconsin - Milwaukee, 2018.
Composite steel frame -- reinforced concrete (RC) core wall structures are often used in high-rise buildings. It is commonly assumed that reinforced concrete walls carry lateral loads such as earthquake loads, while steel frames carry gravity loads. As a result, lateral loads are directly applied to wall elements during a typical structural analysis. This design based on this simplification can be adequate for most structural members except the connections between steel girders and RC walls. This study focuses on the tensile loads on girder-wall connections for composite building structures in earthquakes.
ISBN: 9780438024625Subjects--Topical Terms:
195981
Civil engineering.
Seismic Tensile Force on Steel Girder-Concrete Wall Connections in High-Rise Composite Building Structures.
LDR
:03289nmm a2200325 4500
001
547583
005
20190513114557.5
008
190715s2018 ||||||||||||||||| ||eng d
020
$a
9780438024625
035
$a
(MiAaPQ)AAI10816167
035
$a
(MiAaPQ)uwm:12146
035
$a
AAI10816167
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Hui, Yuchen.
$3
826912
245
1 0
$a
Seismic Tensile Force on Steel Girder-Concrete Wall Connections in High-Rise Composite Building Structures.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2018
300
$a
125 p.
500
$a
Source: Masters Abstracts International, Volume: 57-06.
500
$a
Adviser: Jian Zhao.
502
$a
Thesis (M.S.)--The University of Wisconsin - Milwaukee, 2018.
520
$a
Composite steel frame -- reinforced concrete (RC) core wall structures are often used in high-rise buildings. It is commonly assumed that reinforced concrete walls carry lateral loads such as earthquake loads, while steel frames carry gravity loads. As a result, lateral loads are directly applied to wall elements during a typical structural analysis. This design based on this simplification can be adequate for most structural members except the connections between steel girders and RC walls. This study focuses on the tensile loads on girder-wall connections for composite building structures in earthquakes.
520
$a
Computer models were created for a 28-story composite structures recently built in Chongqing China. SAP2000 was used because detailed finite element models are available for RC shear walls and slabs without high computational costs, and a variety of earthquake analyses are available such as effective lateral load analyses and time history analyses. Different from typical analyses for design, floor slabs are modeled using shell elements such that the earthquake induced inertia force are properly positioned in the structure model. In addition, a gap is created between floor slabs and RC walls to better represent the slab-wall interfaces created by stage construction.
520
$a
The analysis results indicated that 1) a significant amount (more than 50 percent) of floor inertia forces is transferred to core walls through steel girders and girder-wall connections; 2) the total floor inertia force is directly related to the acceleration responses at floor levels; 3) the tensile forces on girder-wall connections also include that created by incompatible deformations between RC core walls and steel frames, especially at lower levels.
520
$a
All previous studies on the girder-wall connections are on their load resisting capacity. This study is a demand analysis and critical step towards a reasonable safe design for composite structures. Future studies must include realistic models of the connections and other components such as embedded reinforcements. Shake table tests of building models are also critical in order to verify the demand analyses. The demand analyses will result in a set of reasonable design loads for engineers to safely design composite build structures in seismic regions.
590
$a
School code: 0263.
650
4
$a
Civil engineering.
$3
195981
690
$a
0543
710
2
$a
The University of Wisconsin - Milwaukee.
$b
Engineering.
$3
826913
773
0
$t
Masters Abstracts International
$g
57-06(E).
790
$a
0263
791
$a
M.S.
792
$a
2018
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10816167
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000163762
電子館藏
1圖書
學位論文
TH 2018
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10816167
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入