語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
High resolution fluorescence microsc...
~
Ajo-Franklin, Caroline Marie.
High resolution fluorescence microscopy of membrane interfaces.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
High resolution fluorescence microscopy of membrane interfaces.
作者:
Ajo-Franklin, Caroline Marie.
面頁冊數:
123 p.
附註:
Adviser: Steven G. Boxer.
附註:
Source: Dissertation Abstracts International, Volume: 65-09, Section: B, page: 4551.
Contained By:
Dissertation Abstracts International65-09B.
標題:
Chemistry, Biochemistry.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3145448
ISBN:
049604351X
High resolution fluorescence microscopy of membrane interfaces.
Ajo-Franklin, Caroline Marie.
High resolution fluorescence microscopy of membrane interfaces.
- 123 p.
Adviser: Steven G. Boxer.
Thesis (Ph.D.)--Stanford University, 2004.
Cellular membranes are functional interfaces that control the flow of information between cells and their environment. It is well established that lateral (x-y) membrane fluidity allows in-plane associations and rearrangements in response to external stimuli, thus resulting in the transduction of signals across the membrane. However, it is also increasing apparent that small perturbations in out-of-plane (z) structure due to membrane bending and the topography of interacting proteins in opposing membranes play an important role in signal transduction.
ISBN: 049604351XSubjects--Topical Terms:
226900
Chemistry, Biochemistry.
High resolution fluorescence microscopy of membrane interfaces.
LDR
:03532nmm _2200265 _450
001
162849
005
20051017073529.5
008
090528s2004 eng d
020
$a
049604351X
035
$a
00149350
040
$a
UnM
$c
UnM
100
0
$a
Ajo-Franklin, Caroline Marie.
$3
227994
245
1 0
$a
High resolution fluorescence microscopy of membrane interfaces.
300
$a
123 p.
500
$a
Adviser: Steven G. Boxer.
500
$a
Source: Dissertation Abstracts International, Volume: 65-09, Section: B, page: 4551.
502
$a
Thesis (Ph.D.)--Stanford University, 2004.
520
#
$a
Cellular membranes are functional interfaces that control the flow of information between cells and their environment. It is well established that lateral (x-y) membrane fluidity allows in-plane associations and rearrangements in response to external stimuli, thus resulting in the transduction of signals across the membrane. However, it is also increasing apparent that small perturbations in out-of-plane (z) structure due to membrane bending and the topography of interacting proteins in opposing membranes play an important role in signal transduction.
520
#
$a
The relevant size scale (nanometers) and the nature of these soft interfaces pose significant challenges towards probing these structures. The resolution of most optical microscopies is limited by diffraction to hundreds of nanometers, while these interfaces are inaccessible to high-resolution scanning probe microscopies. In the following, we describe three fluorescence microscopy methods tailored towards of the goal being able to detect these nanometer-scale changes at membrane interfaces in real time: variable incidence angle total internal reflection fluorescence microscopy (VIA-TIRFM), an evanescent wave microscopy, and fluorescence interference contrast microscopy (FLIC), and variable incidence angle fluorescence interference contrast microscopy (VIA-FLIC), both interferometric techniques. These methods utilize structured illumination, which is illumination that varies in z, to encode z-position in the observed fluorescence intensity. Modulation of the structured illumination allows the z-position of fluorescent objects to be quantitatively determined. Improvements to the existing techniques allow us to demonstrate resolution on the order of tens of nanometers using VIA-TIRFM and nanometer resolution using FLIC. Both of these techniques have their own advantages and disadvantages. VIA-TIRFM can probe z-structure of localized structures, however alignment issues make it difficult to routinely implement. In contrast, FLIC is a very simple method that is well suited for studying z-position of uniformly labeled fluorescent structures that extend over tens of microns, but typically cannot probe localized structures. To capture the advantages of both techniques, we present a novel imaging technique, VIA-FLIC, which preserves the experimental simplicity of FLIC, but adds the ability to z-image isolated objects like VIA-TIRFM. The developments in VIA-TIRFM, FLIC , and VIA-FLIC presented provide improved methods of examining z-structure at cellular and model membrane interfaces with nanometer resolution.
590
$a
School code: 0212.
650
# 0
$a
Chemistry, Biochemistry.
$3
226900
690
$a
0487
710
0 #
$a
Stanford University.
$3
212607
773
0 #
$g
65-09B.
$t
Dissertation Abstracts International
790
$a
0212
790
1 0
$a
Boxer, Steven G.,
$e
advisor
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3145448
$z
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3145448
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000001342
電子館藏
1圖書
學位論文
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3145448
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入