Language:
English
繁體中文
Help
圖資館首頁
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Liquid-phase cavity ring-down spectr...
~
Bechtel, Kate L.
Liquid-phase cavity ring-down spectroscopy and its application as a chromatographic detector.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Liquid-phase cavity ring-down spectroscopy and its application as a chromatographic detector.
Author:
Bechtel, Kate L.
Description:
122 p.
Notes:
Adviser: Richard N. Zare.
Notes:
Source: Dissertation Abstracts International, Volume: 65-09, Section: B, page: 4543.
Contained By:
Dissertation Abstracts International65-09B.
Subject:
Chemistry, Analytical.
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3145465
ISBN:
0496043684
Liquid-phase cavity ring-down spectroscopy and its application as a chromatographic detector.
Bechtel, Kate L.
Liquid-phase cavity ring-down spectroscopy and its application as a chromatographic detector.
- 122 p.
Adviser: Richard N. Zare.
Thesis (Ph.D.)--Stanford University, 2004.
A new liquid-phase absorption detector is developed that demonstrates a minimum detectable absorbance of 10-8 absorbance units (AU). This value is more than 40 times lower than commercially available UV-Vis detectors. This new detector is a result of the extension of cavity ring-down spectroscopy (CRDS), a primarily gas-phase technique, to the liquid phase.
ISBN: 0496043684Subjects--Topical Terms:
224793
Chemistry, Analytical.
Liquid-phase cavity ring-down spectroscopy and its application as a chromatographic detector.
LDR
:03067nmm _2200301 _450
001
162858
005
20051017073530.5
008
090528s2004 eng d
020
$a
0496043684
035
$a
00149359
040
$a
UnM
$c
UnM
100
0
$a
Bechtel, Kate L.
$3
228003
245
1 0
$a
Liquid-phase cavity ring-down spectroscopy and its application as a chromatographic detector.
300
$a
122 p.
500
$a
Adviser: Richard N. Zare.
500
$a
Source: Dissertation Abstracts International, Volume: 65-09, Section: B, page: 4543.
502
$a
Thesis (Ph.D.)--Stanford University, 2004.
520
#
$a
A new liquid-phase absorption detector is developed that demonstrates a minimum detectable absorbance of 10-8 absorbance units (AU). This value is more than 40 times lower than commercially available UV-Vis detectors. This new detector is a result of the extension of cavity ring-down spectroscopy (CRDS), a primarily gas-phase technique, to the liquid phase.
520
#
$a
Liquid-phase CRDS is accomplished by incorporating a specially designed flow cell into the ring-down cavity. The flow cell minimizes optical losses by allowing p-polarized light to refract through the cell interfaces at Brewster's angle. This flow cell has been coupled to the output of an HPLC separation, enabling the detection of analytes by CRDS.
520
#
$a
The detection limit of the liquid-phase CRDS detector was improved through the use of a single-mode continuous-wave (cw) laser source at 488 nm. Its narrow linewidth enabled excitation of a single cavity mode, resulting in shot-to-shot variations in the ring-down time constant as low as 0.04%. Furthermore, through improved cell characterization, ring-down time constants with the same flow cell and cavity length were nearly 6 mus. The baseline noise (rms) for this system during an HPLC separation of the same analytes was 6.7 x 10-8 AU. These results clearly illustrate the value of liquid-phase CRDS and its use as an absorption detector for HPLC measurements.
520
#
$a
This technique was initially demonstrated by the separation and detection of a series of anthraquinones using a pulsed laser source at 470 nm. Ring-down time constants with the Brewster's angle flow cell, having an interior optical pathlength of 0.3 mm, were up to 2.5 mus in a 1-m cavity. The baseline noise level (rms) of this system was 3.2 x 10-6 AU, rivaling the best commercial UV-Vis detector, which exhibits a baseline noise of 3.0 x 10-6 AU. The CRDS detector performance, while notable, was limited in this case because of the nature of the light source: excitation of multiple cavity modes resulted in a 1% shot-to-shot variation in the ring-down time constant.
590
$a
School code: 0212.
650
# 0
$a
Chemistry, Analytical.
$3
224793
650
# 0
$a
Physics, Optics.
$3
226935
690
$a
0486
690
$a
0752
710
0 #
$a
Stanford University.
$3
212607
773
0 #
$g
65-09B.
$t
Dissertation Abstracts International
790
$a
0212
790
1 0
$a
Zare, Richard N.,
$e
advisor
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3145465
$z
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3145465
based on 0 review(s)
ALL
電子館藏
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
000000001351
電子館藏
1圖書
學位論文
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Multimedia file
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3145465
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login