Language:
English
繁體中文
Help
圖資館首頁
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
A quantitative evaluation of dry-sen...
~
Stanford University.
A quantitative evaluation of dry-sensor electroencephalography.
Record Type:
Electronic resources : Monograph/item
Title/Author:
A quantitative evaluation of dry-sensor electroencephalography.
Author:
Uy, E. Timothy.
Description:
155 p.
Notes:
Adviser: Patrick Suppes.
Notes:
Source: Dissertation Abstracts International, Volume: 66-04, Section: B, page: 1944.
Contained By:
Dissertation Abstracts International66-04B.
Subject:
Biophysics, Medical.
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3171697
ISBN:
9780542084478
A quantitative evaluation of dry-sensor electroencephalography.
Uy, E. Timothy.
A quantitative evaluation of dry-sensor electroencephalography.
- 155 p.
Adviser: Patrick Suppes.
Thesis (Ph.D.)--Stanford University, 2005.
Accuracy of the EEG is paramount in the medical diagnosis of epilepsy, in experimental psychology and in the burgeoning field of brain-computer interface. Without a sufficiently accurate measurement, the advantages of dry sensors remain a moot point. However, even after nearly a decade, demonstrations of dry EEG accuracy with respect to wet have been limited to visual comparison of short snippets of spontaneous EEG, averaged event-related potentials or plots of power spectrum. In this dissertation, I propose a detailed methodology based on single-trial EEG classification for comparing dry EEG sensors to their wet counterparts. Applied to a set of commercially fabricated dry sensors, this work reveals that dry sensors can perform as well their wet counterparts with careful screening and attention to the bandwidth of interest.
ISBN: 9780542084478Subjects--Topical Terms:
227040
Biophysics, Medical.
A quantitative evaluation of dry-sensor electroencephalography.
LDR
:02771nmm _2200277 _450
001
170657
005
20061228142211.5
008
090528s2005 eng d
020
$a
9780542084478
035
$a
00242687
040
$a
UnM
$c
UnM
100
0
$a
Uy, E. Timothy.
$3
244685
245
1 2
$a
A quantitative evaluation of dry-sensor electroencephalography.
300
$a
155 p.
500
$a
Adviser: Patrick Suppes.
500
$a
Source: Dissertation Abstracts International, Volume: 66-04, Section: B, page: 1944.
502
$a
Thesis (Ph.D.)--Stanford University, 2005.
520
#
$a
Accuracy of the EEG is paramount in the medical diagnosis of epilepsy, in experimental psychology and in the burgeoning field of brain-computer interface. Without a sufficiently accurate measurement, the advantages of dry sensors remain a moot point. However, even after nearly a decade, demonstrations of dry EEG accuracy with respect to wet have been limited to visual comparison of short snippets of spontaneous EEG, averaged event-related potentials or plots of power spectrum. In this dissertation, I propose a detailed methodology based on single-trial EEG classification for comparing dry EEG sensors to their wet counterparts. Applied to a set of commercially fabricated dry sensors, this work reveals that dry sensors can perform as well their wet counterparts with careful screening and attention to the bandwidth of interest.
520
#
$a
Neurologists, neuroscientists, and experimental psychologists study electrical activity within the brain by recording voltage fluctuations at the scalp. This is electroencephalography (EEG). In conventional or "wet" EEG, scalp abrasion and use of electrolytic paste are required to insure good electrical connection between sensor and skin. Repeated abrasion quickly becomes irritating to subjects, severely limiting the number and frequency of sessions. Several groups have produced "dry" EEG sensors that do not require abrasion or conductive paste. These, in addition to sidestepping the issue of abrasion, promise to reduce setup time from about 30 minutes with a technician to less than 30 seconds without one. The availability of such an instrument would (1) reduce the cost of brain-related medical care, (2) lower the barrier of entry on brain experimentation, and (3) allow individual subjects to contribute substantially more data without fear of abrasion or fatigue.
590
$a
School code: 0212.
650
# 0
$a
Biophysics, Medical.
$3
227040
650
# 0
$a
Physics, Electricity and Magnetism.
$3
227483
690
$a
0607
690
$a
0760
710
0 #
$a
Stanford University.
$3
212607
773
0 #
$g
66-04B.
$t
Dissertation Abstracts International
790
$a
0212
790
1 0
$a
Suppes, Patrick,
$e
advisor
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3171697
$z
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3171697
based on 0 review(s)
ALL
電子館藏
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
000000002455
電子館藏
1圖書
學位論文
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Multimedia file
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3171697
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login