Language:
English
繁體中文
Help
圖資館首頁
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Electromagnet control and efficient ...
~
Matter, Nathaniel Ivan.
Electromagnet control and efficient imaging in prepolarized MRI.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Electromagnet control and efficient imaging in prepolarized MRI.
Author:
Matter, Nathaniel Ivan.
Description:
127 p.
Notes:
Adviser: Albert Macovski.
Notes:
Source: Dissertation Abstracts International, Volume: 67-05, Section: B, page: 2751.
Contained By:
Dissertation Abstracts International67-05B.
Subject:
Engineering, Electronics and Electrical.
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3219334
ISBN:
9780542707698
Electromagnet control and efficient imaging in prepolarized MRI.
Matter, Nathaniel Ivan.
Electromagnet control and efficient imaging in prepolarized MRI.
- 127 p.
Adviser: Albert Macovski.
Thesis (Ph.D.)--Stanford University, 2006.
Magnetic resonance imaging (MRI) uses magnetic fields to acquire cross-sectional medical images with a rich variety of contrast methods for identifying pathology in the body, all without ionizing radiation or other harmful side effects. Prepolarized magnetic resonance imaging (PMRI) uses a fundamentally different magnet architecture than conventional MRI to take advantage of the benefits of acquiring image data at a low magnetic field while achieving the better signal-to-noise ratio of a high magnetic field. Whereas a conventional MRI scanner uses a static background magnetic field generated with superconducting coils or a permanent magnet, a PMRI scanner uses two independently pulsed copper electromagnets.
ISBN: 9780542707698Subjects--Topical Terms:
226981
Engineering, Electronics and Electrical.
Electromagnet control and efficient imaging in prepolarized MRI.
LDR
:03261nmm _2200301 _450
001
180577
005
20080111103743.5
008
090528s2006 eng d
020
$a
9780542707698
035
$a
00311602
040
$a
UMI
$c
UMI
100
0
$a
Matter, Nathaniel Ivan.
$3
264153
245
1 0
$a
Electromagnet control and efficient imaging in prepolarized MRI.
300
$a
127 p.
500
$a
Adviser: Albert Macovski.
500
$a
Source: Dissertation Abstracts International, Volume: 67-05, Section: B, page: 2751.
502
$a
Thesis (Ph.D.)--Stanford University, 2006.
520
#
$a
Magnetic resonance imaging (MRI) uses magnetic fields to acquire cross-sectional medical images with a rich variety of contrast methods for identifying pathology in the body, all without ionizing radiation or other harmful side effects. Prepolarized magnetic resonance imaging (PMRI) uses a fundamentally different magnet architecture than conventional MRI to take advantage of the benefits of acquiring image data at a low magnetic field while achieving the better signal-to-noise ratio of a high magnetic field. Whereas a conventional MRI scanner uses a static background magnetic field generated with superconducting coils or a permanent magnet, a PMRI scanner uses two independently pulsed copper electromagnets.
520
#
$a
The primary advantages of PMRI include the ability to image adjacent to metal prostheses in the body, lower scanner cost, and the possibility for novel contrast mechanisms that require a variable magnetic field. These benefits come at the cost of limited flexibility, however PMRI can perform standard clinical musculoskeletal imaging with almost the same efficiency as conventional MRI.
520
#
$a
This work addressed three engineering challenges in PMRI: design of the pulsing electronics for the polarizing magnet, design of the control system for the readout magnet, and design of efficient imaging methods. The high-field polarizing magnet was rapidly pulsed with a capacitor storage system but required a leakage current bypass network to minimize current in the off state. The low-field readout magnet was powered with a precise control system that offered both maximum regulation and optimal system damping to minimize transient switching disturbances. Even with optimal magnet control, the residual field errors can cause significant imaging artifacts unless the system RF transmit and receive are properly phase shifted with either software or hardware solutions.
520
#
$a
Through improved design of the magnet electronics and the successful implementation of fast 3D imaging sequences, the Stanford PMRI system can now achieve standard clinical contrast and resolution for imaging in vivo human wrists. Additional upgrades to the PMRI system will bring the image SNR closer to that of clinical scanners, but PMRI already outperforms MRI in the presence of metal.
590
$a
School code: 0212.
650
# 0
$a
Engineering, Electronics and Electrical.
$3
226981
650
# 0
$a
Health Sciences, Radiology.
$3
227298
690
$a
0544
690
$a
0574
710
0 #
$a
Stanford University.
$3
212607
773
0 #
$g
67-05B.
$t
Dissertation Abstracts International
790
$a
0212
790
1 0
$a
Macovski, Albert,
$e
advisor
791
$a
Ph.D.
792
$a
2006
856
4 0
$u
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3219334
$z
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3219334
based on 0 review(s)
ALL
電子館藏
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
000000007442
電子館藏
1圖書
學位論文
TH
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Multimedia file
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3219334
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login