Redistributing pollution: Exposure implications of a shift toward distributed electricity generation in California.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Redistributing pollution: Exposure implications of a shift toward distributed electricity generation in California.
Author:
Heath, Garvin Adair.
Description:
493 p.
Notes:
Adviser: William W. Nazaroff.
Notes:
Source: Dissertation Abstracts International, Volume: 68-02, Section: B, page: 1211.
Contained By:
Dissertation Abstracts International68-02B.
Subject:
Environmental Sciences.
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3253895
Redistributing pollution: Exposure implications of a shift toward distributed electricity generation in California.
Heath, Garvin Adair.
Redistributing pollution: Exposure implications of a shift toward distributed electricity generation in California.
- 493 p.
Adviser: William W. Nazaroff.
Thesis (Ph.D.)--University of California, Berkeley, 2006.
Small-scale distributed electricity generation (DG) technologies have been promoted for their many benefits as compared to the traditional paradigm of large, centralized power plants. To evaluate the implications for human inhalation exposure resulting from a shift toward DG, I utilized Gaussian dispersion modeling to conduct a GIS-based inhalation exposure assessment of existing and hypothetical power-generation facilities in California. Most of the dissertation examines twenty-five existing central station power plants (CS) compared to selected DG technologies hypothetically deployed in the downtown areas of the 11 most populous cities in California. A complementary analysis compares statewide inhalation exposure resulting from different scenarios of widespread DG deployment in the commercial sector of California in year 2010 to a scenario of no shift toward DG. Metrics employed to summarize the exposure impacts of DG- and CS-based electricity generation include the intake fraction (iF), the intake-to-delivered-energy ratio (IDER) and the population inhalation intake rate. The iF is the fraction of emitted mass attributable to a source that is inhaled by an exposed population. The iF was determined for populations living within 100 km of each source, using an annual cycle of meteorological conditions typical of the long-term observational record and incorporating population-based, lifetime average breathing rates. The IDER is the attributable population intake per unit of electricity delivered to the place of use, computed as an intake fraction multiplied by an emission factor. Intake rate was computed either as the intake fraction multiplied by an emissions rate or as the IDER multiplied by the rate of delivery of electricity to users. Pollutants evaluated include a primary conserved species (primary PM2.5), a primary decaying species (formaldehyde), and a mixed primary and secondary decaying group of species (nitrogen oxides, or NOx). Other important secondary pollutants, such as ozone, were not assessed. The DG technologies considered in this dissertation include natural gas-fired turbines, internal combustion engines and microturbines, fuel cells (with hydrogen supplied by on-site natural gas reformers) and diesel internal combustion engines. Throughout most of the dissertation, post-combustion emission controls were assumed not to be utilized for any DG technology. For most scenarios considered in the statewide exposure assessment, the examined DG technologies were assumed to meet the current California best available control technology standard for NOx (32 mg kWh-1).Subjects--Topical Terms:
212393
Environmental Sciences.
Redistributing pollution: Exposure implications of a shift toward distributed electricity generation in California.
LDR
:03608nmm _2200253 _450
001
180767
005
20080111103842.5
008
090528s2006 eng d
035
$a
00311794
040
$a
UMI
$c
UMI
100
0
$a
Heath, Garvin Adair.
$3
264352
245
1 0
$a
Redistributing pollution: Exposure implications of a shift toward distributed electricity generation in California.
300
$a
493 p.
500
$a
Adviser: William W. Nazaroff.
500
$a
Source: Dissertation Abstracts International, Volume: 68-02, Section: B, page: 1211.
502
$a
Thesis (Ph.D.)--University of California, Berkeley, 2006.
520
#
$a
Small-scale distributed electricity generation (DG) technologies have been promoted for their many benefits as compared to the traditional paradigm of large, centralized power plants. To evaluate the implications for human inhalation exposure resulting from a shift toward DG, I utilized Gaussian dispersion modeling to conduct a GIS-based inhalation exposure assessment of existing and hypothetical power-generation facilities in California. Most of the dissertation examines twenty-five existing central station power plants (CS) compared to selected DG technologies hypothetically deployed in the downtown areas of the 11 most populous cities in California. A complementary analysis compares statewide inhalation exposure resulting from different scenarios of widespread DG deployment in the commercial sector of California in year 2010 to a scenario of no shift toward DG. Metrics employed to summarize the exposure impacts of DG- and CS-based electricity generation include the intake fraction (iF), the intake-to-delivered-energy ratio (IDER) and the population inhalation intake rate. The iF is the fraction of emitted mass attributable to a source that is inhaled by an exposed population. The iF was determined for populations living within 100 km of each source, using an annual cycle of meteorological conditions typical of the long-term observational record and incorporating population-based, lifetime average breathing rates. The IDER is the attributable population intake per unit of electricity delivered to the place of use, computed as an intake fraction multiplied by an emission factor. Intake rate was computed either as the intake fraction multiplied by an emissions rate or as the IDER multiplied by the rate of delivery of electricity to users. Pollutants evaluated include a primary conserved species (primary PM2.5), a primary decaying species (formaldehyde), and a mixed primary and secondary decaying group of species (nitrogen oxides, or NOx). Other important secondary pollutants, such as ozone, were not assessed. The DG technologies considered in this dissertation include natural gas-fired turbines, internal combustion engines and microturbines, fuel cells (with hydrogen supplied by on-site natural gas reformers) and diesel internal combustion engines. Throughout most of the dissertation, post-combustion emission controls were assumed not to be utilized for any DG technology. For most scenarios considered in the statewide exposure assessment, the examined DG technologies were assumed to meet the current California best available control technology standard for NOx (32 mg kWh-1).
590
$a
School code: 0028.
650
# 0
$a
Environmental Sciences.
$3
212393
650
# 0
$a
Engineering, Environmental.
$3
212478
690
$a
0768
690
$a
0775
710
0 #
$a
University of California, Berkeley.
$3
212474
773
0 #
$g
68-02B.
$t
Dissertation Abstracts International
790
$a
0028
790
1 0
$a
Nazaroff, William W.,
$e
advisor
791
$a
Ph.D.
792
$a
2006
856
4 0
$u
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3253895
$z
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3253895
based on 0 review(s)
ALL
電子館藏
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
000000007632
電子館藏
1圖書
學位論文
TH
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Multimedia file
http://libsw.nuk.edu.tw:81/login?url=http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3253895
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login