Towards offline PET monitoring at a ...
~
SpringerLink (Online service)
Towards offline PET monitoring at a cyclotron-based proton therapy facilityexperiments and Monte Carlo simulations /
Record Type:
Electronic resources : Monograph/item
Title/Author:
Towards offline PET monitoring at a cyclotron-based proton therapy facilityby Matthias Wurl.
Reminder of title:
experiments and Monte Carlo simulations /
Author:
Wurl, Matthias.
Published:
Wiesbaden :Springer Fachmedien Wiesbaden :2016.
Description:
xv, 86 p. :ill. (some col.), digital ;24 cm.
Contained By:
Springer eBooks
Subject:
Tomography, Emission.
Online resource:
http://dx.doi.org/10.1007/978-3-658-13168-5
ISBN:
9783658131685$q(electronic bk.)
Towards offline PET monitoring at a cyclotron-based proton therapy facilityexperiments and Monte Carlo simulations /
Wurl, Matthias.
Towards offline PET monitoring at a cyclotron-based proton therapy facility
experiments and Monte Carlo simulations /[electronic resource] :by Matthias Wurl. - Wiesbaden :Springer Fachmedien Wiesbaden :2016. - xv, 86 p. :ill. (some col.), digital ;24 cm. - BestMasters. - BestMasters..
Monte Carlo Modeling of a Clinical Proton Beam -- Low-Dose Envelope and Field Size Factor -- PET Activation Studies.
Matthias Wurl presents two essential steps to implement offline PET monitoring of proton dose delivery at a clinical facility, namely the setting up of an accurate Monte Carlo model of the clinical beamline and the experimental validation of positron emitter production cross-sections. In the first part, the field size dependence of the dose output is described for scanned proton beams. Both the Monte Carlo and an analytical computational beam model were able to accurately predict target dose, while the latter tends to overestimate dose in normal tissue. In the second part, the author presents PET measurements of different phantom materials, which were activated by the proton beam. The results indicate that for an irradiation with a high number of protons for the sake of good statistics, dead time losses of the PET scanner may become important and lead to an underestimation of positron-emitter production yields. Contents Monte Carlo Modeling of a Clinical Proton Beam Low-Dose Envelope and Field Size Factor PET Activation Studies Target Groups Researchers and students in the field of medical physics with focus on particle therapy Medical physicists at proton therapy facilities The Author Matthias Wurl wrote his Master's Thesis at the chair of Medical Physics at the Ludwig-Maximilians University Munich. He is now a PhD student at the same department, working on transmission imaging with laser-accelerated ions.
ISBN: 9783658131685$q(electronic bk.)
Standard No.: 10.1007/978-3-658-13168-5doiSubjects--Topical Terms:
276849
Tomography, Emission.
LC Class. No.: RC78.7.T62
Dewey Class. No.: 616.07575
Towards offline PET monitoring at a cyclotron-based proton therapy facilityexperiments and Monte Carlo simulations /
LDR
:02590nmm a2200325 a 4500
001
489535
003
DE-He213
005
20161104151115.0
006
m d
007
cr nn 008maaau
008
161213s2016 gw s 0 eng d
020
$a
9783658131685$q(electronic bk.)
020
$a
9783658131678$q(paper)
024
7
$a
10.1007/978-3-658-13168-5
$2
doi
035
$a
978-3-658-13168-5
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
RC78.7.T62
072
7
$a
PHP
$2
bicssc
072
7
$a
SCI051000
$2
bisacsh
082
0 4
$a
616.07575
$2
23
090
$a
RC78.7.T62
$b
W967 2016
100
1
$a
Wurl, Matthias.
$3
748089
245
1 0
$a
Towards offline PET monitoring at a cyclotron-based proton therapy facility
$h
[electronic resource] :
$b
experiments and Monte Carlo simulations /
$c
by Matthias Wurl.
260
$a
Wiesbaden :
$b
Springer Fachmedien Wiesbaden :
$b
Imprint: Springer Spektrum,
$c
2016.
300
$a
xv, 86 p. :
$b
ill. (some col.), digital ;
$c
24 cm.
490
1
$a
BestMasters
505
0
$a
Monte Carlo Modeling of a Clinical Proton Beam -- Low-Dose Envelope and Field Size Factor -- PET Activation Studies.
520
$a
Matthias Wurl presents two essential steps to implement offline PET monitoring of proton dose delivery at a clinical facility, namely the setting up of an accurate Monte Carlo model of the clinical beamline and the experimental validation of positron emitter production cross-sections. In the first part, the field size dependence of the dose output is described for scanned proton beams. Both the Monte Carlo and an analytical computational beam model were able to accurately predict target dose, while the latter tends to overestimate dose in normal tissue. In the second part, the author presents PET measurements of different phantom materials, which were activated by the proton beam. The results indicate that for an irradiation with a high number of protons for the sake of good statistics, dead time losses of the PET scanner may become important and lead to an underestimation of positron-emitter production yields. Contents Monte Carlo Modeling of a Clinical Proton Beam Low-Dose Envelope and Field Size Factor PET Activation Studies Target Groups Researchers and students in the field of medical physics with focus on particle therapy Medical physicists at proton therapy facilities The Author Matthias Wurl wrote his Master's Thesis at the chair of Medical Physics at the Ludwig-Maximilians University Munich. He is now a PhD student at the same department, working on transmission imaging with laser-accelerated ions.
650
0
$a
Tomography, Emission.
$3
276849
650
0
$a
Proton synchrotrons.
$3
748090
650
0
$a
Monte Carlo method.
$3
186286
650
1 4
$a
Physics.
$3
179414
650
2 4
$a
Particle and Nuclear Physics.
$3
456401
650
2 4
$a
Theoretical, Mathematical and Computational Physics.
$3
376743
650
2 4
$a
Biophysics and Biological Physics.
$3
376965
710
2
$a
SpringerLink (Online service)
$3
273601
773
0
$t
Springer eBooks
830
0
$a
BestMasters.
$3
676593
856
4 0
$u
http://dx.doi.org/10.1007/978-3-658-13168-5
950
$a
Physics and Astronomy (Springer-11651)
based on 0 review(s)
ALL
電子館藏
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
000000127046
電子館藏
1圖書
電子書
EB RC78.7.T62 W967 2016
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Multimedia file
http://dx.doi.org/10.1007/978-3-658-13168-5
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login