Dynamic isolation technologies in negative pressure isolation wardsby Zhonglin Xu, Bin Zhou.
Author:
Xu, Zhonglin.
other author:
Zhou, Bin.
Published:
Singapore :Springer Singapore :2017.
Description:
x, 216 p. :ill., digital ;24 cm.
Contained By:
Springer eBooks
Subject:
Hospital buildingsHeating and ventilation.
Online resource:
http://dx.doi.org/10.1007/978-981-10-2923-3
ISBN:
9789811029233$q(electronic bk.)
Dynamic isolation technologies in negative pressure isolation wards
Xu, Zhonglin.
Dynamic isolation technologies in negative pressure isolation wards
[electronic resource] /by Zhonglin Xu, Bin Zhou. - Singapore :Springer Singapore :2017. - x, 216 p. :ill., digital ;24 cm.
Importance of negative pressure isolation ward -- Three misunderstandings in design process of negative pressure isolation ward -- Principle and technology of dynamic isolation -- Air distribution design in negative pressure isolation ward -- Determination of air change rate in negative pressure isolation ward -- Safety of exhaust and return air is prerequisite -- Design essentials for negative pressure isolation ward.
This book presents novel design principles and technologies for dynamic isolation based on experimental studies. These approaches have now become the local standard in Beijing and are currently being promoted for use nationwide. Further, the book provides details of measures and guidelines for the design process. Departing from the traditional understanding that isolation wards should be designed with high negative pressure, airtight doors and fresh air, it establishes the basis for designing biological clean rooms, including isolation wards, using a simple and convenient scientific approach. This book is intended for designers, engineers, researchers, hospital management staff and graduate students in heating ventilation air conditioning (HVAC), air cleaning technologies and related areas.
ISBN: 9789811029233$q(electronic bk.)
Standard No.: 10.1007/978-981-10-2923-3doiSubjects--Topical Terms:
771231
Hospital buildings
--Heating and ventilation.
LC Class. No.: RA969.4
Dewey Class. No.: 614.46
Dynamic isolation technologies in negative pressure isolation wards
LDR
:02163nmm a2200313 a 4500
001
505734
003
DE-He213
005
20170615155111.0
006
m d
007
cr nn 008maaau
008
171030s2017 si s 0 eng d
020
$a
9789811029233$q(electronic bk.)
020
$a
9789811029226$q(paper)
024
7
$a
10.1007/978-981-10-2923-3
$2
doi
035
$a
978-981-10-2923-3
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
RA969.4
072
7
$a
TN
$2
bicssc
072
7
$a
TEC009020
$2
bisacsh
082
0 4
$a
614.46
$2
23
090
$a
RA969.4
$b
.X8 2017
100
1
$a
Xu, Zhonglin.
$3
676112
245
1 0
$a
Dynamic isolation technologies in negative pressure isolation wards
$h
[electronic resource] /
$c
by Zhonglin Xu, Bin Zhou.
260
$a
Singapore :
$b
Springer Singapore :
$b
Imprint: Springer,
$c
2017.
300
$a
x, 216 p. :
$b
ill., digital ;
$c
24 cm.
505
0
$a
Importance of negative pressure isolation ward -- Three misunderstandings in design process of negative pressure isolation ward -- Principle and technology of dynamic isolation -- Air distribution design in negative pressure isolation ward -- Determination of air change rate in negative pressure isolation ward -- Safety of exhaust and return air is prerequisite -- Design essentials for negative pressure isolation ward.
520
$a
This book presents novel design principles and technologies for dynamic isolation based on experimental studies. These approaches have now become the local standard in Beijing and are currently being promoted for use nationwide. Further, the book provides details of measures and guidelines for the design process. Departing from the traditional understanding that isolation wards should be designed with high negative pressure, airtight doors and fresh air, it establishes the basis for designing biological clean rooms, including isolation wards, using a simple and convenient scientific approach. This book is intended for designers, engineers, researchers, hospital management staff and graduate students in heating ventilation air conditioning (HVAC), air cleaning technologies and related areas.
650
0
$a
Hospital buildings
$x
Heating and ventilation.
$3
771231
650
0
$a
Isolation (Hospital care)
$3
771232
650
1 4
$a
Engineering.
$3
210888
650
2 4
$a
Building Physics, HVAC.
$3
675341
650
2 4
$a
Fluid- and Aerodynamics.
$3
376797
650
2 4
$a
Atmospheric Protection/Air Quality Control/Air Pollution.
$3
274449
650
2 4
$a
Practice and Hospital Management.
$3
738106
700
1
$a
Zhou, Bin.
$3
681518
710
2
$a
SpringerLink (Online service)
$3
273601
773
0
$t
Springer eBooks
856
4 0
$u
http://dx.doi.org/10.1007/978-981-10-2923-3
950
$a
Engineering (Springer-11647)
based on 0 review(s)
ALL
電子館藏
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
000000136669
電子館藏
1圖書
電子書
EB RA969.4 X8 2017
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Multimedia file
http://dx.doi.org/10.1007/978-981-10-2923-3
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login