語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
High-Speed Millimeter-Wave Active Incoherent Fourier Domain Imaging.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
High-Speed Millimeter-Wave Active Incoherent Fourier Domain Imaging.
作者:
Vakalis, Stavros.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, 2022
面頁冊數:
171 p.
附註:
Source: Dissertations Abstracts International, Volume: 84-02, Section: B.
附註:
Advisor: Nanzer, Jeffrey A.
Contained By:
Dissertations Abstracts International84-02B.
標題:
Electromagnetics.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29258338
ISBN:
9798837521843
High-Speed Millimeter-Wave Active Incoherent Fourier Domain Imaging.
Vakalis, Stavros.
High-Speed Millimeter-Wave Active Incoherent Fourier Domain Imaging.
- Ann Arbor : ProQuest Dissertations & Theses, 2022 - 171 p.
Source: Dissertations Abstracts International, Volume: 84-02, Section: B.
Thesis (Ph.D.)--Michigan State University, 2022.
This item must not be sold to any third party vendors.
Millimeter-wave imaging is used in applications such as security screening, remote sensing, medical imaging, and non-destructive testing due to the good penetration characteristics of millimeter-wave radiation which can provide "see-through" capabilities. Electromagnetic signals in the frequency range of 30–300 GHz can penetrate easily through materials like clothing, fog, and smoke, and at the same time provide image reconstruction with fine spatial resolution. Millimeter-wave imaging is typically implemented by means of mechanical or electrical scanning which requires long data acquisition times or a large number of active components. Computational imaging can reduce both the data acquisition time and the number of active components, but this comes at the cost of heavy computational loads, which makes real-time operation challenging. Passive millimeter-wave imaging systems that capture thermal signals and operate similarly to optical cameras, are very costly because they need to employ highly sensitive receivers due to thermal radiation being extremely low power at millimeter-wave frequencies. A paradigm shift is needed in order to advance the current imaging modalities in millimeter-wave frequencies.In this dissertation, I present a newly developed millimeter-wave imaging technique called active incoherent millimeter-wave (AIM) imaging which combines the benefits of active and passive millimeter-wave imaging. This approach combines the high signal-to-noise ratio capabilities of active millimeter-wave imaging systems with the fast image formation potential of passive millimeter-wave imaging systems. The combination is achieved by illuminating the scene with multiple spatially distributed noise transmitters that mimic the randomness of thermal radiation. Because the concept of incoherent noise illumination has not been investigated thoroughly in the literature of millimeter-wave imaging, I discuss design considerations for creating a space-time incoherent transmitter and novel measurements for characterizing space-time incoherence. Starting from my earlier work in microwave frequencies, I present the system design and calibration approach, along with an experimental demonstration of a millimeter-wave active incoherent digital array. The array is capable of generating millimeter-wave video at very high frame rates, and millimeter-wave imaging results of 652 frames per second of a sphere moving in a pendulum motion are included. The scenario of using the stray reflections from a small set of communications transmitters is also examined and I present results using WiFi and fifth-generation (5G) communications signals. I also expand interferometric imaging to three dimensions using a novel pulse modulation as an envelope on the noise signals to provide differentiation along the range dimension. Prior to this work, three-dimensional interferometric millimeter-wave imaging had only been implemented in the near-field region or using three-dimensional volumetric arrays, which pose significant size and volume concerns. A new algorithm for three-dimensional interferometric image formation is presented along with simulated results and experimental measurements.
ISBN: 9798837521843Subjects--Topical Terms:
708560
Electromagnetics.
Subjects--Index Terms:
Incoherence
High-Speed Millimeter-Wave Active Incoherent Fourier Domain Imaging.
LDR
:04372nmm a2200373 4500
001
636140
005
20230501063909.5
006
m o d
007
cr#unu||||||||
008
230724s2022 ||||||||||||||||| ||eng d
020
$a
9798837521843
035
$a
(MiAaPQ)AAI29258338
035
$a
AAI29258338
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Vakalis, Stavros.
$0
(orcid)0000-0003-2532-9702
$3
942485
245
1 0
$a
High-Speed Millimeter-Wave Active Incoherent Fourier Domain Imaging.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2022
300
$a
171 p.
500
$a
Source: Dissertations Abstracts International, Volume: 84-02, Section: B.
500
$a
Advisor: Nanzer, Jeffrey A.
502
$a
Thesis (Ph.D.)--Michigan State University, 2022.
506
$a
This item must not be sold to any third party vendors.
520
$a
Millimeter-wave imaging is used in applications such as security screening, remote sensing, medical imaging, and non-destructive testing due to the good penetration characteristics of millimeter-wave radiation which can provide "see-through" capabilities. Electromagnetic signals in the frequency range of 30–300 GHz can penetrate easily through materials like clothing, fog, and smoke, and at the same time provide image reconstruction with fine spatial resolution. Millimeter-wave imaging is typically implemented by means of mechanical or electrical scanning which requires long data acquisition times or a large number of active components. Computational imaging can reduce both the data acquisition time and the number of active components, but this comes at the cost of heavy computational loads, which makes real-time operation challenging. Passive millimeter-wave imaging systems that capture thermal signals and operate similarly to optical cameras, are very costly because they need to employ highly sensitive receivers due to thermal radiation being extremely low power at millimeter-wave frequencies. A paradigm shift is needed in order to advance the current imaging modalities in millimeter-wave frequencies.In this dissertation, I present a newly developed millimeter-wave imaging technique called active incoherent millimeter-wave (AIM) imaging which combines the benefits of active and passive millimeter-wave imaging. This approach combines the high signal-to-noise ratio capabilities of active millimeter-wave imaging systems with the fast image formation potential of passive millimeter-wave imaging systems. The combination is achieved by illuminating the scene with multiple spatially distributed noise transmitters that mimic the randomness of thermal radiation. Because the concept of incoherent noise illumination has not been investigated thoroughly in the literature of millimeter-wave imaging, I discuss design considerations for creating a space-time incoherent transmitter and novel measurements for characterizing space-time incoherence. Starting from my earlier work in microwave frequencies, I present the system design and calibration approach, along with an experimental demonstration of a millimeter-wave active incoherent digital array. The array is capable of generating millimeter-wave video at very high frame rates, and millimeter-wave imaging results of 652 frames per second of a sphere moving in a pendulum motion are included. The scenario of using the stray reflections from a small set of communications transmitters is also examined and I present results using WiFi and fifth-generation (5G) communications signals. I also expand interferometric imaging to three dimensions using a novel pulse modulation as an envelope on the noise signals to provide differentiation along the range dimension. Prior to this work, three-dimensional interferometric millimeter-wave imaging had only been implemented in the near-field region or using three-dimensional volumetric arrays, which pose significant size and volume concerns. A new algorithm for three-dimensional interferometric image formation is presented along with simulated results and experimental measurements.
590
$a
School code: 0128.
650
4
$a
Electromagnetics.
$3
708560
650
4
$a
Electrical engineering.
$3
454503
653
$a
Incoherence
653
$a
Interferometry
653
$a
Millimeter-wave imaging
653
$a
Noise signals
690
$a
0607
690
$a
0544
710
2
$a
Michigan State University.
$b
Electrical Engineering - Doctor of Philosophy.
$3
915715
773
0
$t
Dissertations Abstracts International
$g
84-02B.
790
$a
0128
791
$a
Ph.D.
792
$a
2022
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29258338
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000223044
電子館藏
1圖書
電子書
EB 2022
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29258338
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入