語系:
繁體中文
English
說明(常見問題)
圖資館首頁
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Fluorescent Carbon Dots With Incorporated DNA Aptamer for the Biosensing of Cocaine /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Fluorescent Carbon Dots With Incorporated DNA Aptamer for the Biosensing of Cocaine /Kaylee Nicole Stinson.
作者:
Stinson, Kaylee Nicole,
面頁冊數:
1 electronic resource (47 pages)
附註:
Source: Masters Abstracts International, Volume: 86-11.
附註:
Advisors: Determan, John Committee members: Bellott, Brian; Jin, Jin.
Contained By:
Masters Abstracts International86-11.
標題:
Physical chemistry.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=32000761
ISBN:
9798314863022
Fluorescent Carbon Dots With Incorporated DNA Aptamer for the Biosensing of Cocaine /
Stinson, Kaylee Nicole,
Fluorescent Carbon Dots With Incorporated DNA Aptamer for the Biosensing of Cocaine /
Kaylee Nicole Stinson. - 1 electronic resource (47 pages)
Source: Masters Abstracts International, Volume: 86-11.
Carbon dots (CDs) are used for biosensing because of their practical application, fluorophoric nature, low toxicity, and abundant precursors. The fluorescence of CDs was used for drug detection when combined with a DNA aptamer that is specifically coded for a target molecule. The negatively charged cocaine DNA aptamer electrostatically binds to the positively charged CD made from malic acid and polyethyleneimine. The DNA aptamer effectively quenched the CDs fluorescence. Once the cocaine was added to the CD-aptamer complex, the aptamer released from the CD as the aptamers preferentially bind to the cocaine molecule. The CD fluorescence was recovered indicating the presence of cocaine. The CD-aptamer complex was tested for specificity by using lidocaine and procaine which are similar in structure to cocaine. Results show that the aptamer has a higher affinity for the drug molecule by uncapping itself from the CD. The uncapping of the aptamer results in an increase in fluorescence intensity. The increase isn't currently linearly proportional to the amount of drug dosed to the system. The salt concentration of the aptamer solution could possibly be interfering with the linearity which is going to be the focus of future research.
English
ISBN: 9798314863022Subjects--Topical Terms:
708580
Physical chemistry.
Subjects--Index Terms:
Biosensing
Fluorescent Carbon Dots With Incorporated DNA Aptamer for the Biosensing of Cocaine /
LDR
:02645nmm a22004213i 4500
001
693699
005
20260511063013.5
006
m o d
007
cr|nu||||||||
008
260819s2025 miu||||||m |||||||eng d
020
$a
9798314863022
035
$a
(MiAaPQD)AAI32000761
035
$a
AAI32000761
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Stinson, Kaylee Nicole,
$e
author.
$3
1010328
245
1 0
$a
Fluorescent Carbon Dots With Incorporated DNA Aptamer for the Biosensing of Cocaine /
$c
Kaylee Nicole Stinson.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2025
300
$a
1 electronic resource (47 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 86-11.
500
$a
Advisors: Determan, John Committee members: Bellott, Brian; Jin, Jin.
502
$b
M.S.
$c
Western Illinois University
$d
2025.
520
$a
Carbon dots (CDs) are used for biosensing because of their practical application, fluorophoric nature, low toxicity, and abundant precursors. The fluorescence of CDs was used for drug detection when combined with a DNA aptamer that is specifically coded for a target molecule. The negatively charged cocaine DNA aptamer electrostatically binds to the positively charged CD made from malic acid and polyethyleneimine. The DNA aptamer effectively quenched the CDs fluorescence. Once the cocaine was added to the CD-aptamer complex, the aptamer released from the CD as the aptamers preferentially bind to the cocaine molecule. The CD fluorescence was recovered indicating the presence of cocaine. The CD-aptamer complex was tested for specificity by using lidocaine and procaine which are similar in structure to cocaine. Results show that the aptamer has a higher affinity for the drug molecule by uncapping itself from the CD. The uncapping of the aptamer results in an increase in fluorescence intensity. The increase isn't currently linearly proportional to the amount of drug dosed to the system. The salt concentration of the aptamer solution could possibly be interfering with the linearity which is going to be the focus of future research.
546
$a
English
590
$a
School code: 6012
650
4
$a
Physical chemistry.
$3
708580
650
4
$a
Nanoscience.
$3
220425
650
4
$a
Chemical engineering.
$3
206267
653
$a
Biosensing
653
$a
Cocaine
653
$a
Fluorescence intensity
653
$a
Drug molecule
690
$a
0494
690
$a
0565
690
$a
0542
710
2
$a
Western Illinois University.
$b
Chemistry.
$3
660204
720
1
$a
Determan, John
$e
degree supervisor.
773
0
$t
Masters Abstracts International
$g
86-11.
790
$a
6012
791
$a
M.S.
792
$a
2025
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=32000761
筆 0 讀者評論
全部
電子館藏
館藏
1 筆 • 頁數 1 •
1
條碼號
館藏地
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
000000263002
電子館藏
1圖書
學位論文
TH
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
多媒體檔案
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=32000761
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入